Introduction
RT510 / RT510TX / RT510RF is a programmable room thermostat used to control room temperature.
Device launching heating system by shorting terminal blocks, simultaneously informing the action and
showing this information on the LCD display. Extended features allows us to use various operating modes
- automatic (time schedules), manual, frost protection or holiday. Before use please read this manual
carefully. Use only AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot
located under the cover. Do not use rechargeable batteries.
Product compliance
This product complies with the essential requirements and other relevant provisions of the following EU Directives:
EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of
Conformity is available on www.saluslegal.com
868.0-868.6MHz; <13dBm
Safety Information
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition.
Product for indoor use only. Installation must be carried out by a qualified person in accordance to national
and EU regulations.
Technical specification
RT510 Thermostat
RT510TX Thermostat
Thermostat supply
2 x AA alkaline batteries 2 x AA alkaline batteries
Thermostat rating max
3 (1) A
-
Voltage free
Outputs
NO / COM / NC
-
terminals
Temperature range
5 - 35°C
5 - 35°C
Temperature accuracy
0.1°C or 0.5°C
0.1°C or 0.5°C
Hysteresis
±0.25°C or ±0.5°C
±0.25°C or ±0.5°C
Radio frequency
-
868 MHz
Dimension [mm]
120x96x27
120x96x27
RXRT510 Receiver
Receiver supply
230 V AC
Receiver rating max
16 (5) A
Outputs
Voltage free NO / COM terminals
Radio frequency
868 MHz
Dimension [mm]
96x96x27
Button functions
RT510 / RT510TX Thermostat
RXRT510 Receiver
3
1
4
2
5
6
8
1. Boost function
6. When in Manual Mode,
ON will turn the boiler on.
2. Manual Mode
7. When in Manual Mode,
3. Frost protection / Holiday Mode
4. Increase button
OFF will turn the boiler off.
5. Decrease button
8. Receiver operates in automatic mode
according to the thermostat
9. Receiver output is controlled
by the On/Off slide switch.
LCD Icon description
1. Day of the week
2. Program number
15
14
13
12
11
3. Program indicator
1
MON
10
4. Settings
TUE
WED
9
THU
5. Temperature measured / set
FRI
SAT
8
6. Boost function
SUN
7
7. Low battery status
2
8. Wireless connection with the receiver
3
4
5
6
9. Heating Mode On
10. Manual Mode On
11. Holiday Mode On
12. Frost Protection Mode On
N
L
13. Temperature unit
COM
14. AM / PM
15. Clock
NO
RT510 Terminals description
Terminal
Description
1 - COM
Common Terminal
2 - NC
Switched Live OFF
3 - NO
Switched Live ON
RXRT510 Receiver terminals description
Terminal
Description
NO
Switch Terminal
COM
Common Switch Terminal
NO COM L N
L, N
Supply (230 V AC)
DIP Switch Settings
The DIP Switches can be found on the rear of your thermostat.
Control feature
TPI
Span
Operation
When TPI is selected on DIP
When Span is selected
switch № 2, the DIP switch №
on DIP switch № 2,
1 is functional. You can choose
the DIP switch № 1 is
the Cycles Per Hour between
not functional.
a lower comfort level (6CPH)
temperature accuracy of
and a higher comfort level
your thermostat is set to
(9CPH).
± 0.25 °C.
RT510 Wiring diagram
AC 230 V
L
7
9
N
RT510TX Wiring diagram
Note: If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done.
N
L
COM
NO
N
L
COM
NO
MAX
16 (5) A
N
L
AC 230 V
L
Setting the time
1
2
MAX
3 (1) A
MON
SELECT
SET
TEST / PAIRING
Press
TEST / PAIRING
3 sec 3 sec
SELECT
SET
OR
M
Press the buttons SELECT and SET
N
together for 3 sec.
SELECT
SET
3
4
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
Press
Press SELECT to confirm.
SELECT
SET
5
6
SELECT
SET
MON
The
SELECT
SET
TEST / PAIRING
Press
SELECT
SET
TEST / PAIRING
Press SELECT to confirm.
SELECT
SET
7
AC 230 V
L
MON
MAX
3 (1) A
SELECT
SET
MAX
3 (1) A
SELECT
Press SELECT to confirm.
SELECT
9
OR
M
SELECT
OR
M
N
THU
SELECT
SET
SELECT
Press SET to confirm.
Programming - automatic mode
In this mode, user can set the schedules for thermostat (temperature setpoints for specific periods of
time). To do this, firstly choose programming mode: "5-2" (business days + weekend) or "24h" (each
day separately) using parameter d04 from Installer mode. Programmed schedules should use all
time periods.
1
N
L
THU
SELECT
SET
AC 230 V
L
SELECT
Press the SET button to start programming.
SELECT
3
SELECT
MAX
3 (1) A
OR
N
L
MON
M
TUE
WED
THU
FRI
SELECT
SET
OR
M
SELECT
N
Press SELECT to confirm.
5
SELECT
MON
TUE
WED
THU
FRI
SELECT
SET
TEST / PAIRING
SELECT
SET
or
to select the hour format.
SELECT
Press SELECT to confirm.
TEST / PAIRING
SELECT
7
SELECT
MON
TUE
MON
WED
THU
FRI
SELECT
SET
TEST / PAIRING
SELECT
SET
or
to set the hour.
SELECT
SELECT
SET
TEST / PAIRING
Press SELECT to confirm.
TEST / PAIRING
9
TEST / PAIRING
MON
TUE
WED
MON
THU
FRI
SELECT
SET
SELECT
SET
TEST / PAIRING
or
to set the minutes.
SELECT
SELECT
SET
TEST / PAIRING
Press SELECT to confirm.
TEST / PAIRING
8
MON
TEST / PAIRING
SELECT
SET
TEST / PAIRING
Press
or
to set day of the week.
TEST / PAIRING
TEST / PAIRING
SET
SELECT
SET
SET
TEST / PAIRING
10
TEST / PAIRING
SET
THU
TEST / PAIRING
SELECT
SET
TEST / PAIRING
Thermostat will return to the main screen.
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
N
L
COM
2
NO
MAX
OR
16 (5) A
N
L
M
MON
TUE
WED
THU
FRI
TEST / PAIRING
SELECT
SET
TEST / PAIRING
Use the
or
button to select day / days
from which you want to start programming.
SELECT
SET
TEST / PAIRING
TEST / PAIRING
SET
TEST / PAIRING
SET
4
SET
TEST / PAIRING
MON
TUE
WED
THU
FRI
TEST / PAIRING
TEST / PAIRING
SELECT
SET
Use the
or
button to set the hour
SET
TEST / PAIRING
to start the program #1.
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
6
SET
TEST / PAIRING
MON
TUE
WED
THU
FRI
TEST / PAIRING
SELECT
SET
TEST / PAIRING
Use the
or
button to set the minutes
SET
TEST / PAIRING
to start the program #1.
SELECT
SET
TEST / PAIRING
SET
TEST / PAIRING
8
TEST / PAIRING
SET
MON
TUE
WED
THU
FRI
TEST / PAIRING
SELECT
SET
TEST / PAIRING
Use the
or
button
SET
TEST / PAIRING
to set the temperature for program #1.
SELECT
SET
TEST / PAIRING
TEST / PAIRING
SELECT
SET
10
SELECT
SET
TEST / PAIRING
MON
TUE
WED
THU
FRI
TEST / PAIRING
SELECT
SET
TEST / PAIRING
Follow steps 4-9,
TEST / PAIRING
to define programs 2-6.
SELECT
SET
TEST / PAIRING
SET
Press SET button to end programming.

Advertisement

loading

Summary of Contents for Salus RT510RF

  • Page 1 SELECT TEST / PAIRING according to the thermostat Note: If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done. Press SET to confirm. 9. Receiver output is controlled by the On/Off slide switch.
  • Page 2 - it will be maintained until next time interval starts according to programmed in Installer Mode in d03 parameter. Note: If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done. 3 sec schedule.

This manual is also suitable for:

Rt510Rt510bcRt510txRxrt510