Installation instructions

Check that the electrical rating shown on the showers matches the mains supply. A
competent installer must undertake all installations. If in any doubt, advice and
assistance should be sought from a qualified plumber and/or electrician. Installations
and wiring must conform to current BS7671 IEE regulations (UK)
WARNING! DO NOT INSTALL THIS SHOWER IN A ROOM
WHERE IT MAY BE SUBJECT TO FREEZING
We recommend that the installation be done in the following
sequence.
a) Fixing the shower to the wall
b) Plumbing
c) Electrical connections
a) Fixing the shower to the wall
1. Position the riser rail at the height recommended in
diagram 5 and mark its position.
2. Position the heater so the sides of the unit are vertical
and the top is level with, or up to 0.6 metres (2ft)
maximum below the top of the riser rail. Choose a flat
piece of wall to avoid the possibility of distorting the
back plate thus making the front cover a poor fit.
3. Adjust the positions to get the most convenient
arrangement taking the following into account.
a) The possible need to use the handset over the sink
for hair washing etc.
b) The heater must not be mounted in the direct spray
from the showerhead.
c) The handset must not be able to come into contact
with any used water in the bath or basin. If it can,
even after the hose has been retained by the hose
retainer (see diagram 13), then a vacuum breaker
must be fitted. It should be noted that these devices
are liable to minor leakage so they must be
positioned so that any drips are not detrimental.
4. Fix the riser rail with screws provided. The fixing holes
at the base of the brackets will be disclosed by
removing the plastic fronts. Assemble as shown in
diagram 13.
5. Decide the position of the electrical cable inside the unit. If top or bottom entry is chosen
(according to diagram 6), cut away the walls of the back-plate as shown in diagram 8.
There is also the option to fit the cable from the rear in the channel provided.
6. Decide the cut away position of entry of the cold water pipe into the unit. Cut away the
back-plate and front cover as shown in diagram 7 or 8. There is also the option to have
6