22

Steam connection

The water supply to the machine should be fitted
with manual shut-off valves and filters to facili-
tate installation and servicing.
The connection hose must be of type ISO/107-
198 or equivalent. Connection size at filter:
DN 15 (BSP 1/2").
Steam pressure required:
• minimum: 50 kPa (0.5 kp/cm
• maximum: 800 kPa (8 kp/cm
• Remove the cover (A).
23
• Mount the articulated nipple to the steam
24
valve.
• Mount the steam valve on the machine.
25
• Mount nipple, strainer and elbow. Note the
26
direction of the strainer. Mount steam hose to
the elbow.
Check that there are no sharp angles or bends
on the connected steam hose.
• Mount the hose with wires between steam
27
valve and machine.
Connect wires in the steam valve.
Connect ground cable to the terminal ground
connection.
Mount the cable connector on X46 on distri-
bution card.
Installation
)
2
)
2
23
24
25
26
27
A
5861
5862
586
5864
X46
660

Hide quick links: