Inlet pipes connected to the machine must be equipped with a manual shut-off valve to facilitate installation and serv-
icing. The connection hose must be of type ISO/1307- 1983 or equivalent.
Connection size at filter: DN 15 (BSP 1/2").
Demount the top panel (A). Demount the casing (B).
Mount the nipple to the steam valve. Mount the steam valve on the machine. Mount nipple, strainer and elbow. Note
the direction of the strainer. Mount steam hose to the elbow. Check that there are no sharp angles or bends on the
connected steam hose.
Mount the hose with wires between steam valve and machine. Connect the wires to the steam valve. Connect ground
cable to the terminal ground connection. Connect the "HEAT" cable connector to the "HEAT" terminal on the I/O
board.
"HEAT"
Steam pressure required:
• minimum: 50 kPa (0.5 kp/cm
• maximum: 800 kPa (8 kp/cm
• recommended: 600 kPa (6 kp/cm
Note!
A steam heated machine is only intended to use clean steam.