Quick Reference Guide
Vibration Meter
805
Flashlight
riešenia na presné meranie™
Vibration sensor
Elso Philips Service; tel: +421 32 6582410
email: elso@elso.sk; web:
www.elso.sk
LCD
IR temperature
sensor
USB port
Audio port
Power on/off
External
sensor port
Measure
Backlight on/off
Navigation
Flashlight on/off
Enter
Save
Memory
Setup
Status LED
Connector cover
PN 4045074 May 2012 © 2012 Fluke Corporation. All rights reserved. Printed in China.
Measurement Tips
LED Status
90˚
SAVE
Green On
Green Off
Red On
Error, insufficient
Green Off
Push the sensor tip onto the test
Data measurement
surface, on solid metal, as close
is complete.
force or time
as possible to the bearing. Apply
duration, no data
the compression force until
measurement.
green LED is off.
Sensor Placement
Push  before you
apply the Meter to the test
surface.
Vibration Severity Per ISO 10816-1
Machine
Class I
Class II
Class II
Class III
Small
Medium
Large Rigid
Large Soft
in/s
mm/s
Machines
Machines
Foundation
Foundation
0.01
0.28
0.02
0.45
0.03
0.71
GOOD
0.04
1.12
0.07
1.80
0.11
2.80
SATISFACTORY
0.18
4.50
0.28
7.10
UNSATISFACTORY
0.44
11.20
0.70
18.00
1.10
28.00
UNACCEPTABLE
1.77
45.90
For the best measurements, use these guidelines:
Push  and position the Meter perpendicular to the test surface.
Push the sensor tip onto the test surface, on solid metal, and as close to the bearing as possible
until the green LED turns on.
Hold Meter in position with a consistent force until the green LED turns off. The test results show
on the display.
Severity Scale
No repair action is recommended.
No immediate repair action is required. Increase the frequency
of measurements and monitor the condition of the machine.
Have a knowledgeable vibration technician conduct
more advanced tests at the earliest opportunity. Consider
maintenance action at the next planned downtime or
maintenance period.
Have a knowledgeable vibration technician conduct more
advanced tests as soon as possible. Consider immediate
shutdown of the machine to make repairs and prevent failure.
Crest Factor + (CF+)
The Meter operates with a proprietary algorithm called Crest Factor + (CF+). To
make interpretation easy for the user, the CF+ value is shown in a range from
1 to 16 in the severity scale. The higher the CF+ value is, the more the bearing
damage.
The CF+ value shows for every measurement in the Bearing field on the Meter
display. Push  and  to toggle between the CF+ value and the high frequency
vibration level in units of acceleration.
Meter Display
High Frequency
Bearing Vibration
4,000 Hz to 20,000 Hz
(CF+)
Overall Vibration
Overall Vibration
Frequency Range:
10 Hz to 1,000 Hz
Temperature
IR Temperature
20 ◦ C to 200 ◦ C
Data Transfer
Export Data
Trending
The product CD supplies a custom Microsoft Excel template that helps you to evaluate
the measurements. See Export Data in the Users Manual for more information about
the template and measurement plots.

Advertisement

loading

Summary of Contents for Fluke 805

  • Page 1 LED turns on. • Hold Meter in position with a consistent force until the green LED turns off. The test results show on the display. PN 4045074 May 2012 © 2012 Fluke Corporation. All rights reserved. Printed in China.
  • Page 2 LIMITED WARRANTY AND LIMITATION OF LIABILITY tings menu. This Fluke product will be free from defects in material and workmanship for one year from the The Meter does not include a rechargeable date of purchase. This warranty does not cover fuses, disposable batteries, or damage from Save to Existing Setup function.