Page 1
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS, for the User and the Installer Comfort E 100 - 130 - 160 - 210 - 240 A1002860 - 661Y1600 • D...
TABLE OF CONTENTS GENERAL RECOMMENDATIONS ...............4 PRODUCT INFORMATION ................5 Energy labelling ............................... 5 Rating Plate ................................. 6 USER'S GUIDE ....................7 Control Panel ................................7 APPLIANCE DESCRIPTION .................8 Models - Comfort E 100 - 130 - 160 - 210 - 240 ....................8 TECHNICAL CHARACTERISTICS .............10 Dimensions and main Characteristics ....................10...
Page 3
TABLE OF CONTENTS STARTING UP ....................21 Safety Instructions to Fill the Tank ......................21 Filling ....................................22 Checks before Starting up ..........................24 Starting Up Procedure ............................24 MAINTENANCE ..................25 Periodic Checks by the User ........................25 Annual Maintenance ............................25 Draining ..................................26 Bringing back into Service after Maintenance ................26 Replacement of the Electric Heating Element ................28...
The part number (P/N) and serial number (S/N) of the appliance are indicated on its rating plate and must be provided to ACV in case of warranty claim. Failure to do rating plate and must be provided to ACV in case of warranty claim. Failure to do so will make the claim void.
USER'S GUIDE USER'S GUIDE CONTROL PANEL CONTROL PANEL Heating Heating element ON element OFF Key : 1. Control thermostat [60/80°C] - To set the domestic hot water (DHW) temperature. 2. Fuse FF 12,5 Amp - To provide an electric protection to the appliance. 3.
APPLIANCE DESCRIPTION APPLIANCE DESCRIPTION MODELS - Comfort E 100 - 130 - 160 - 210 - 240 Storage water tanks, to be installed vertically on the wall, that can work within a heating installa- tion, or independently as electric domestic hot water heater only. The Comfort E tank is equipped with one 2200 W heating element controlled by the thermostat and by the Summer/Winter switch on the appliance control panel.
TECHNICAL CHARACTERISTICS ELECTRICAL CHARACTERISTICS Comfort E Main characteristics Rated voltage Rated frequency Electrical consumption with 2,200 2,200 2,200 2,200 2,200 electrical heating element Rated current with electrical heating element Wiring diagram 230 Volt connection cord Control thermostat [60/80°C] Manual reset high limit thermostat [89°C max.] Summer / Winter switch Fuse FF 12,5 A Electric heating element...
TECHNICAL CHARACTERISTICS PERFORMANCE DHW performance Comfort E Peak flow at 45 °C * L/10' Peak flow at 45 °C * L/60' 1156 1560 Constant flow at 45 °C * 1309 Power drawn * Heating time with the 2.2 kW 2 h 43' 3 h 27' 4 h 20' 5 h 37'...
INSTALLATION INSTALLATION SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS General remarks General remarks • • Connections (electrical, hydraulic) must be carried out in accordance with Connections (electrical, hydraulic) must be carried out in accordance with applicable standards and regulations. applicable standards and regulations. •...
Page 15
• • ACV recommends using a pre-set thermostatic mixing valve in order to provide ACV recommends using a pre-set thermostatic mixing valve in order to provide hot water at a maximum of 60°C. hot water at a maximum of 60°C.
INSTALLATION PACKING CONTENTS All appliances are delivered, tested and packaged separately. Package • One Comfort E hot water tank. • One multilingual Installation, Operation and Maintenance Instructions. • One energy label • One wall-mounting kit with support and flow diverter General Remarks •...
• Hot water can burn! ACV recommends using a pre- set thermostatic mixing valve in order to provide hot water at a maximum of 60°C. Essential instructions for the correct operation of the system •...
Page 19
INSTALLATION CONNECTION TO THE PRIMARY CIRCUIT (Typ. vertical installation on a wall) Primary circuit filling valve 2. Charging pump 3. Check valve 4. Primary circuit stop valve Expansion vessel 6. Pressure gauge Safety valve 8. Drain valve Stop valve Cold water Hot water Comfort E : A1002860 - 661Y1600 •...
INSTALLATION COMFORT E TANK USED AS ELECTRIC DHW TANK ONLY Do not power the heating element if the oustide tank is not filled and bled. System filling valve Safety valve calibrated to 3 bar Expansion vessel Isolation valve, heating system Pressure gauge This connection to be plugged.
STARTING UP STARTING UP SAFETY INSTRUCTIONS TO FILL THE TANK SAFETY INSTRUCTIONS TO FILL THE TANK Essential instructions for the safety of persons and the environment Essential instructions for the safety of persons and the environment • • The DHW tank must always be filled and pressurised before filling and pressurising The DHW tank must always be filled and pressurised before filling and pressurising the primary circuit.
STARTING UP FILLING FILLING Essential instruction for the correct operation of the system Essential instruction for the correct operation of the system • • The DHW tank must always be filled and pressurised before filling and pressurising The DHW tank must always be filled and pressurised before filling and pressurising the primary circuit.
Page 23
STARTING UP Figure 1 Cold water Hot water Figure 2 Comfort E : A1002860 - 661Y1600 • D...
STARTING UP CHECKS BEFORE STARTING UP • Check that the safety valves (DHW and primary) are correctly installed and that the outlets are connected to the sewer. • Check that the DHW tank and the primary circuit are filled with water. •...
MAINTENANCE MAINTENANCE PERIODIC CHECKS BY THE USER • Check the pressure of the primary circuit pressure gauge: it should be between 0.5 and 1.5 bar. • Visually inspect, on a regular basis, the valves, connections and accessories in order to detect any leaks or malfunction.
MAINTENANCE DRAINING Essential instruction for the safety of persons and the environment • The water coming out of the drain valve is very hot and can cause very severe burns. Make sure the area around the hot water flow is clear of people. Essential instruction for the electrical safety •...
Page 27
MAINTENANCE Figure 3 Cold water Hot water Figure 4 Comfort E : A1002860 - 661Y1600 • D...
MAINTENANCE REPLACEMENT OF THE ELECTRIC HEATING ELEMENT • Switch off and disconnect the mains power supply to the appliance. • Be careful with the high temperature of the cylinder. • Drain the primary tank. Max = 5,5 Nm Min = 4,8 Nm Comfort E : A1002860 - 661Y1600 •...
MAINTENANCE FAULT FINDING What to do if the domestic hot water is not heated anymore? Check the power supply. Check the proper operation of the boiler and the control thermostat of the tank. Check if the load pump works properly and replace if necessary. Check the fuse and replace if necessary.