OP1S Operator Control Panel

4.2 Change slave

During bus operation, a specific slave can be selected via the OP1S with the "Change
slave" function without any re-plugging. Starting from the basic menu, the "Change slave"
function is selected with the "Lower"/"Raise" key and activated with "P". The user is then
requested to enter a slave address.
P
Ê Ê
Ì Ì
MotionControl
Change slave
Download
Address:00
Delete data
# Change slave
After the slave address has been entered with "Raise"/"Lower" and confirmed with "P", a
change is made to the required slave and the display returns to the basic menu. If the
slave cannot be found, an error message is output.