Installation; Location - Zanussi ZCE569NW1 Instruction Book

Table of Contents

Advertisement

Installation

It is mandatory that all operations required for
the installation be carried out by QUALIFIED
PERSONNEL in accordance with existing rules
and regulations.
The appliance must be installed in accordance
with " Y " specification (EN60.335-2.6). The
cooker must not be installed higher than the
cooker hob top.
Please ensure that when the appliance is
installed it is easily accessible for the
engineer in the event of a breakdown.

Location

The cooker has been registered as a "Class Y"
appliance according to Fire Rick Regulations.
Any adjacent cabinets or walls must not exceed
the cooker's height.
The cooker may be located in a kitchen, a
kitchen/diner or bed sitting room, but not in a
bathroom or shower room.
The minimum distance combustible material can
be fitted above the cooker in line with the edges
of the cooker is 69 cm (see fig.)
The cooker should be placed only on
the floor, but not on the base.
Before your appliance is connected to the
mains electricity supply, check to ensure that
the voltage and the frecquency shown in the
rating label corresponds with your supply
voltage.
This appliance must be earthed.
min 15 cm
61 cm
21