Daikin Maverick I MPS A03C Installation And Maintenance Manual page 39

Heating & cooling
Table of Contents

Advertisement

Table 26: Airflow Performance—MPS A05C, 208V, 230V, 460V
Airflow Performance – 5 Ton [17.6 Kw] Three Phase Belt Drive
Air
Flow
CFM
[L/s]
0.1 [.02]
0.2 [.05]
0.3 [.07]
RPM
W
RPM
W
RPM
1400
[661]
1500
[708]
1600
— 766 478 816 511 865 549 913 593 960 643 1006 698 1051 758 1095 824 1137 895 1179 972 1220 1055 1260 1143 1300 1231
[755]
1700
— 785 509 833 546 881 589 928 637 974 690 1018 749 1062 813 1105 883 1146 959 1187 1040 1227 1126 1265 1218 1303 1310
[802]
1800
— 755 505 804 550 851 591 898 637 943 689 988 747 1031 810 1074 878 1115 952 1156 1031 1195 1116 1234 1207 1271 1302 1308 1397
[850]
1900
716 491 776 560 823 600 869 645 915 695 959 751 1003 812 1045 879 1086 951 1127 1029 1166 1113 1204 1202 1242 1296 1278 1396 1314 1496
[897]
2000
745 562 797 615 843 658 889 707 933 762 976 821 1018 887 1059 958 1099 1034 1139 1116 1177 1203 1214 1296 1250 1394 1285 1498 1320 1602
[944]
2100
773 637 819 679 864 726 908 779 951 837 993 901 1034 970 1074 1045 1113 1125 1151 1211 1188 1303 1224 1399 1259 1502 1293 1609 —
[991]
2200
797 706 842 751 886 803 929 860 971 922 1011 990 1051 1063 1090 1142 1128 1226 1165 1316 1200 1411 1235 1512 1269 1618 —
[1038]
2300
822 783 865 833 908 888 950 949 990 1015 1030 1087 1069 1164 1106 1247 1143 1335 1179 1429 1213 1528 1247 1633 1279 1743 —
[1085]
2400
847 870 889 924 931 983 971 1048 1011 1118 1049 1194 1087 1275 1123 1362 1159 1454 1193 1551 1227 1655 1259 1763 1291 1878 —
[1133]
2500
873 966 914 1023 954 1087 994 1155 1032 1229 1069 1309 1106 1394 1141 1485 1175 1581 1209 1683 1241 1790 1272 1903
[1179]
NOTE: L-DRIVE left of bold line, M-DRIVE right of bold line
Drive Package
Motor H.P. [W]
Blower Sheave
Motor Sheave
Turns Open
0
RPM
967
Component Air Resistance
Component
1600 [755]
Wet Coil
0.070
Downflow
0.072
R.S.I. Economizer
0.08
R.A. Damper
NOTES:
1. Performance shown with dry coil & standard 2" [50.8 mm] filters.
2. Standard CFM @ .075 ibs./cu.ft.
3. Motor efficiency = 80%
4. BHP = Watts × Motor Efficiency/746.
5. Add component resistance to duct static to determine E.S.P as shown on charts
[ ] Designates Metric Conversions
www.DaikinApplied.com
External Static Pressure - Inches of Water [kPa]
0.4 [.10]
0.5 [.12]
0.6 [.15]
W
RPM
W
RPM
W
RPM
W
— 784 466 835 497 886 533 935 574 983 621 1030 674 1077 732 1122 795 1166 864 1209 939 1251 1019 1292 1104
— 800 484 850 519 899 558 947 604 994 655 1040 711 1085 773 1129 841 1172 914 1214 992 1255 1076 1295 1166
L
3/4 [559]
6.9" Pitch Diameter
2.8" – 3.8" Pitch Diameter
2
1
3
900
936
855
1800 [850]
0.085
0.080
0.09
Capacity 5 Ton [17.6 kW] 14 SEER
Voltage 208/230/460/575, 3-Phase
0.7 [.17]
0.8 [.20]
0.9 [.22]
1.0 [.25]
RPM
W
RPM
W
RPM
W
RPM
4
5
0
816
769
1248
Standard Indoor Airflow – CFM [L/s]
2000 [944]
2200 [1038]
Resistance – Inches Water [kPa]
0.100
0.110
0.086
0.093
0.10
0.11
39
P
erforManCe
1.1 [.27]
1.2 [.30]
1.3 [.32]
W
RPM
W
RPM
W
RPM
W
M
1 [746]
6.9" Pitch Diameter
4.0" – 5.0" Pitch Diameter
3
1
2
1123
1203
1163
2400 [1133]
0.120
0.100
0.12
IM 970-2 • MAVERICK I ROOFTOP
d
aTa
1.4 [.35]
1.5 [.37]
RPM
W
RPM
W
4
5
1078
1042
2600 [1227]
0.125
0.107
0.13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents