Viessmann Vitoflame 100 Service Instructions Manual page 46

Pressure-jet oil burner
Table of Contents

Advertisement

Specification
Specification
Rated boiler output
Connections
Suction and return
lines on the supplied oil
hoses
Max. permissible
pre-charge pressure
in the supply lines
(with pipe circuits)
In combination with Vitorond 100, type VR2B
Rated boiler output
Burner output stage 1/2
Burner type
DIN registration
Voltage
Frequency
Power consumption
Motor speed
Version
Oil pump rate
Connections
Suction and return lines on the
supplied oil hoses
Max. permissible pre-charge
pressure in the supply lines
(with pipe circuits)
In conjunction with Vitorond 200, type VD2
Rated boiler output
Burner output stage 1/2
Burner type
DIN registration
Voltage
Frequency
Power consumption
Motor speed
Version
Oil pump rate
Corresponds to the rated heat input of the boiler.
*4
46
(cont.)
kW
R (female thread)
kW
kW
*4
V
Hz
W
rpm
l/h
R (female
thread)
kW
*4
kW
V
Hz
W
rpm
l/h
180
VEH III-1VR
125
95/136
VEH III-1VD
VEH III-2VD
5G1037/08S
340
235
2
80
60/87
VEH III-2VR
5G1037/08S
230
50
250
2800
Two-stage
70
2
160
122/174
VEH III-3VD
230
50
360
2800
Two-stage
70
300
100
76/109
280
195
149/213
407