Names and Functions of Parts

2.1 Names and Functions of Parts

2.1.1 GT707

 Names and functions of parts
No.
Name
Touch screen
Attachment fittings
Operation mode setting
switches
Power supply terminal
block (24 V DC)
USB port
SD memory card slot
COM port
(D-sub 9-pin male
connector)
Waterproof packing
Battery cover
Mounting position of
battery
Mounting position of
connector for battery
2-2
Function
Various screens are displayed here. Switches can be operated and data entered
simply by touching the touch screen. A sheet is affixed to the touch panel to
protect it from scrathes when shipping. Remove it before using the GT.
Secure the unit to the installation panel at four points using the fittings and
screws provided with the unit.
Switches for setting the operation mode at the time of power-on. Using these
switches enables to inhibit to move to the system menu or select the memory
clear display.
Power supply terminal for operation and functional ground terminal. Supplies 24
VDC. Be sure to conduct functional ground when there is an influence of noise.
Connector for the connection between the unit and a PC when using the screen
creation tool software GTWIN. A commercal USB cable is used.
An SD memory card is inserted. SD memory cards can be used for copying
screen data and our PLC programs, and used for the logging function, alarm
history function and SD recipe function.
Communication (RS-232C) port for the connection between the unit and an
external device such as a PLC and microcomputer board.
This assures that the front panel is waterproof.
When using a battery for GT707 clock (AFPABAT001) to be separately
purchased, open this battery cover to install it. When the battery for the clock is
attached, the GT internal clock works even if the power supply is off.