E600I Ac Power Modules - Dell Force10 E300 Quick Start Manual

Hide thumbs Also See for Force10 E300:
Table of Contents

Advertisement

Step
Task
Replace the safety cover and tighten the captive screw with a #2 Phillips
8
screwdriver.
Turn the Over Current Protector to the ON position.
9
Turn the remote power source (the circuit breaker panel) to the ON
10
position.

E600i AC Power Modules

The E600i requires a minimum of two AC Power Supplies.
Power Supply Input
220 VAC
100 VAC
The chassis has four power supply slots. You may install AC power supplies in
any slot.
WARNING: Class 1 laser product.
The 2500W AC Power Supply Unit is capable of operating at either 100 VAC or
220 VAC.
CAUTION: Before removing and replacing a power supply unit, determine if
the E600i is in full redundancy or non-redundant mode. Operating in non-
redundant mode will require a complete system power off when removing and
replacing a power supply.
NOTE: Do not mix power supply versions. Installing a 2500W-AC2 power supply
into a chassis with 2500W-AC power supplies already installed may result in
unpredictable behavior. FTOS will declare an alarm when the PSUs are mixed.
To install an AC power supply:
Step
Task
Verify that the power switch on the power supply is in the OFF position.
1
Orient the power supply handle to the left, and slide the backplane
2
connector end into a power supply slot.
Minimum (N)
3
2
Installing the Hardware
Redundancy
N+1
N+1
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Force10 e600iForce10 e1200i

Table of Contents