Contents
Use this document as a guide to install and wire the 1746-BTM barrel temperature control
module.
For this information
For this reference information

Installation Instructions

See page
2
3
4
4
4
5
9
See page
14
Publication 1746-IN020B-EN-P - July 2002

Advertisement

Table of Contents
loading

Summary of Contents for Allen-Bradley 1746-BTM

  • Page 1: Table Of Contents

    Installation Instructions Barrel Temperature Control Module Cat. No. 1746-BTM Contents Use this document as a guide to install and wire the 1746-BTM barrel temperature control module. For this information See page Important User Information Prevent Electrostatic Discharge How to Get the Related User Manual Determine the Module’s Chassis Power Requirement...
  • Page 2: Important User Information

    (to include intellectual property liability) for actual use based upon the examples shown in this publication. Allen-Bradley publication SGI-1.1, Safety Guidelines for the Application, Installation and Maintenance of Solid-State Control (available from your local Rockwell Automation office), describes some important differences between solid-state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication.
  • Page 3: Prevent Electrostatic Discharge

    Also, see the appropriate sections in this publication, as well as the Allen-Bradley publication 1770-4.1 ("Industrial Automation Wiring and Grounding Guidelines"), for additional installation requirements pertaining to this equipment.
  • Page 4: How To Get The Related User Manual

    Barrel Temperature Control Module How to Get the Related User Manual The following table describes the related user manual that is available for this module. To order a copy or to view or download an online version, visit The Automation Bookstore at: www.theautomationbookstore.com For information about: See this document:...
  • Page 5: Install The Module

    Barrel Temperature Control Module Install the Module To install your module into the chassis: 1. Turn off the chassis power supply. If you insert or remove the module while backplane power is on, an WARNING electrical arc can occur. This could cause an explosion in hazardous location installations.
  • Page 6 Barrel Temperature Control Module 5. To remove, press the releases at the top and bottom of the module, and slide the module out of the chassis slot. card guides top and bottom releases retaining clips Publication 1746-IN020B-EN-P - July 2002...
  • Page 7 Barrel Temperature Control Module Remove/Install the Removable Terminal Block The module ships with an attached an 18-position removable terminal block (RTB). When you install the module, it is not necessary to remove the RTB. If you ever need to remove it, follow this procedure: 1.
  • Page 8 Barrel Temperature Control Module 2. Make certain the color of the RTB mathces the color band on the module. Inserting a wired RTB on an incorrect module can damage the module’s ATTENTION circuitry when power is restored. 3. View the write–on label to identify the slot, chassis and module type. SLOT RACK MODULE...
  • Page 9: Wire The Rtb

    Barrel Temperature Control Module Wire the RTB Use the following illustration to wire the RTB: Retaining Screw CJC A+ Channel 0+ CJC Assembly CJC A- Channel 0- Channel 1+ Channel 1- Do NOT use these connections Channel 2+ Channel 2- Channel 3+ CJC B+ CJC Assembly...
  • Page 10 Barrel Temperature Control Module Wiring Guidelines Follow these guidelines when planning your system wiring. • To limit the pickup of electrical noise, keep thermocouple and millivolt signal wires away from power and load lines. • For high immunity to electrical noise, use Alpha 5121 (shielded, twisted pair) or equivalent wire for millivolt sensors;...
  • Page 11 Barrel Temperature Control Module Preparing and Wiring the Cables To prepare and connect cable leads and drain wires, follow these steps: Remove the foil shield and drain wire from sensor-end of the cable Signal Wires Drain Wire Extract the drain wire but Signal Wires remove the foil shield, at the module-end of the...
  • Page 12 Barrel Temperature Control Module 7. At the source-end of cables from mV devices (see following figure): • remove the drain wire and foil shield • apply shrink wrap as an option • connect to mV devices keeping the leads short Make unshielded wires as short as possible.
  • Page 13 Barrel Temperature Control Module The following information applies when Informations sur l’utilisation de cet équipement operating this equipment in hazardous en environnements dangereux : locations: Products marked “CL I, DIV 2, GP A, B, C, D” are Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne suitable for use in Class I Division 2 Groups A, B, C, conviennent qu’à...
  • Page 14: Specifications

    Barrel Temperature Control Module Specifications Module Location SLC chassis - any I/O module slot except 0 Input from System Backplane 5Vdc @ 0.110 A, 24Vdc @ 0.085A Thermocouple Types b, c, d, e, j, k, n, r, s, t Input Voltage -50 to +50mV and -100 to +100mV Number of Channels 4 (backplane and channel-to-channel isolated)
  • Page 15 Barrel Temperature Control Module Notes: Publication 1746-IN020B-EN-P - July 2002...
  • Page 16 Please contact your local Rockwell Automation representative for the return procedure. Allen-Bradley, Rockwell Automation, SLC, SLC 500, and TechConnect are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication 1746-IN020B-EN-P - July 2002 PN 957689-86 Supersedes Publication 1746-5.20 - February 1999...