Timing Chart Table - HIOS BLT-AY-71 Instruction Manual

Power supply for automatic brushless screwdriver
Hide thumbs Also See for BLT-AY-71:
Table of Contents

Advertisement

Timing Chart Table

Note:
◦If a pulse input is to be used for START and RESET, always use an input of 100 mS or more.
◦Set the interval between one START and the next START to 100 mS or more for the reading START settings.
◦Do not change the external input during torque up operations (impact).
◦Always control the input sequence in a single direction when switching between forward and reverse rotation.
No.
Start Type
Timing Chart 01
Pulse Start
Timing Chart 02
Pulse Start
Timing Chart 03
Pulse Start
Timing Chart 04
Pulse Start
Timing Chart 05
Pulse Start
Timing Chart 06
Pulse Start
Timing Chart 07*
Timing Chart 08*
Timing Chart 09*
Pulse Start
Timing Chart 10*
Pulse Start
Timing Chart 11*
Reading Start
Timing Chart 12*
Reading Start
Timing Chart 13*
Reading Start
Timing Chart 14*
Reading Start
Timing Chart 15*
Reading Start
Timing Chart 16*
Reading Start
Timing Chart 17*
Reading Start
Timing Chart 18*
Reading Start
* The timing charts are applied to screwdrivers for counter-clock-wise for automatic BLF brushless screwdriver. Please note that they
are not applied to standard types.
Impact setting value
FOR/HIGH FOR/LOW REV/HIGH REV/LOW
U1
U3
U1
U1
U1
U3
U1
U1
d1
d3
d1
U1
U1
U1
d1
d3
d1
U1
2WS setting
HIGH
HIGH
LOW
LOW
LOW → HIGH
HIGH → LOW
d1
LOW → HIGH
HIGH → LOW
d1
HIGH
HIGH
HIGH
HIGH
LOW
LOW
LOW → HIGH
HIGH → LOW
HIGH
HIGH
Bit rotation
FOR
FOR
FOR
FOR
FOR
FOR
REV
REV
REV → FOR
FOR → REV
FOR
FOR
FOR
FOR
FOR
FOR
REV → FOR
FOR → REV
17