Rotation
Setting of the number of impacts for forward rotation and torque-up trigger
setting
POWER
LOW
FOR
OPE
ON
OFF
DRIVER
Setting of the number of impacts for reverse rotation and torque-up trigger
POWER
FOR OPE
ON
OFF
DRIVER
Setting of rotation speed
POWER
FOR
OPE
ON
OFF
DRIVER
Setting of overtime
POWER
FOR OPE
ON
OFF
DRIVER
To HIGH
This sets the number of impacts in forward rotation and the type of torque-up
trigger.
TUP
F I N
REV
RES
2WS
OVT
When U0/d0 is set, impacts continued to be applied without torque up.
Setting value (initial value: d1)
MODE
ENT
U: UP trigger
d: DOWN trigger
0 to 4: the number of impacts
This is to set the number of impacts in reverse rotation and the type of torque-up
TUP
F I N
REV
RES
2WS
OVT
trigger.
When U0/d0 is set, impacts continued to be applied without torque up.
Note:
When reverse rotation is used for the screwdriver specified with the forward rotation,
MODE
ENT
never fail to set this U0 or d0.
Setting value (initial: value: d0)
U: UP trigger
d: DOWN trigger
0 to 4: the number of impacts
This sets the low rotation speed among 11 steps. For details of setting values and
TUP
F I N
REV
RES
2WS
OVT
rotation speeds, see P.12.
Setting value (initial value: 15)
05 to 15
MODE
ENT
If the automatic screwdriver keeps rotating, this stops it automatically to protect
TUP
F I N
REV
RES
2WS
OVT
this unit and the screwdriver.
Usually, set this in the program on the system including PLC.
Setting value (initial value: t0)
MODE
ENT
t0 to t9 (t1: about 10 sec. to t9: about 90 sec., t0: about 42 minutes)
11