Removal Of P-Module; Removal Of Lamp Unit - Panasonic PT-FW300NTU Service Manual

Hide thumbs Also See for PT-FW300NTU:
Table of Contents

Advertisement

PT-FW300NTU / PT-FW300NTE / PT-FW300NTEA / PT-FW300U / PT-FW300E / PT-FW300EA / PT-F300NTU / PT-F300NTE / PT-F300NTEA / PT-F300U / PT-F300E / PT-F300EA
7. Unscrew the 2 screws and remove the exhaust fan.
8. Unscrew the 3 screws.
9. Lift the power block and unscrew the 2 screws, then
disconnect the lamp connector terminal.
Note:
· Because the lead wire between the power block and
the lamp connector terminal is short, be careful not
to apply excessive force into it.
10. Remove the power block.
11. Unscrew the 5 screws and separate the power unit and the
ballast unit.
12. Unscrew the 4 screws and remove the B/Q-Module.

8.15. Removal of P-Module

1. Remove the power unit according to the steps 1 through 11
in the section 8.14. "Removal of B/Q Module".
2. Unscrew the 4 screws and remove the P-Module.

8.16. Removal of Lamp Unit

1. Loosen the 2 screws until they idle, remove the lamp unit
cover.
2. Loosen the 2 screws until they idle, remove the lamp unit
with the handle.
19