PT-P1SDU / PT-P1SDE / PT-P1SDEA
6. Unscrew the 2 screws and remove the connector cover.
7. Unscrew the 7 screws and remove the J-P.C.Board.
6.5.
Removal of R-P.C.Board
1. Remove the upper case according to the section 6.2.
"Removal of Upper Case".
2. While unhooking the resin hook, remove the R-P.C.Board.
Note:
· Work carefully not to damage the resin hook.
All manuals and user guides at all-guides.com
6.6.
1. Remove the analysis block, LCD block and lens according
to the steps 1 through 6 in the section 6.11. "Removal of
Analysis Block and Lens".
2. Unscrew the 2 screws and remove the thermofuse
attachment fittings.
3. Unscrew the 1 screw and remove the grounding lug.
4. Unscrew the 2 screws and remove the K-P.C.Board.
6.7.
1. Remove the lamp unit according to the section 6.10.
"Removal of Lamp Unit".
2. Remove the upper case according to the section 6.2.
"Removal of Upper Case".
3. Unscrew the 1 screw and remove the grounding metal 2.
4. Unhook each hook, and remove the power holders 3 and 4.
5. Remove the power insulation sheet.
12
Removal of K-P.C.Board
Removal of B/Q-Module