6.6 Daisy Chain between Methods A.1 and B.1

In rare situations where more flat braids need to be terminated for a connector than three per ring terminal
and a mixture of Methods A.1 and B.1 have been used, it is allowable to daisy chain a maximum of two
shields together between a Method A.1 and B.1 termination before terminating to the ring terminal
(Figure
6-7). All other restrictions and instructions for the shield termination set forth in Method A.1 and
B.1 are still applicable.
NOTE
The maximum length of the combined braids should be 4 inches.
Figure 6-7 Shield Termination Technique Methods A.1 and B.1
190-02072-01
Rev. 2
G5 Installation Manual
Page 6-12