B.1.6 Daisy Chain between Methods A and B
In rare situations where more braids need to be terminated for a connector than three per ring terminal and
a mixture of Methods A and B have been used, it is allowable to daisy chain a maximum of two shields
together from a Method A termination to a Method B (Figure B-7). All other restrictions and instructions
for the shield termination technique set forth for Method A and B are still applicable.
NOTE
The maximum length of the combined braids should be approximately 4 inches.
Figure B-7 Daisy Chain between Methods A and B
190-01054-01
Rev. D
GDU 37X Installation Manual
Page B-11