Lennox BCK 020 Installation Operating & Maintenance Manual page 31

Baltic series
Hide thumbs Also See for BCK 020:
Table of Contents

Advertisement

COMMISSIONING report
(8) REFRIGERATION SECTION / SECTION REFRIGERATION
Outdoor Fan Motor Current / Intensité Moteurs Batterie externe:
Motor 1 / Moteur 1
Motor 2 / Moteur 2
Motor 3 / Moteur 3
Motor 4 / Moteur 4
Motor 5 / Moteur 5
Motor 6 / Moteur 6
Compressor Amps COOLING / Intensité
Compresseur MODE FROID
Phase 1
Comp 1
........ A
Comp 2
........ A
Comp 3
........ A
Comp 4
........ A
Check Reversing valves./
Vérifier vannes d'inversion:
Compressor Amps HEATING / Intensité
Compresseur en Pompe à Chaleur
Phase 1
Comp 1
........ A
Comp 2
........ A
Comp 3
........ A
Comp 4
........ A
HP cut out / Coupure HP
Refrigerant charge / Charge réfrigérant
(8)ELECTRIC HEATER SECTION / SECTION RECHAUFFEUR ELECTRIQUE
Type / Type:
..........................................................
st
AMPS 1
stage (Baltic) / Intensité 1
1 ...................
2 ...................
(9) HOT WATER COIL SECTION / SECTION BATTERIE EAU CHAUDE
Check Three Way Valve Movement / Vérification Mouvement Vanne trois voies: Yes/Oui
(10) GAS HEATING SECTION / RAMPE GAZ
Gas Burner N°1 / Brûleur gaz N°1
Size / Taille:
............................
Pipe size/ tuyauterie:
Line press./ press. ligne :
...........................
Check manifold pressure/ Pression injection:
High fire/Grande allure..........Low fire/Petite allure...........
Pressure cut out airflow press switch / Pression coupure
pressostat débit d'air : ........................mbar /Pa
Motor amps
Flue temp /
I moteur:
temp fumées
..........A
......... °C
(11) REMOTE CONTROL BMS CHECK / VERIFICATIONS BMS CONTROL A DISTANCE
Type / Type:
............................
Comments.....................................................................................................................................................................................
.......................................................................................................................................................................................................
.......................................................................................................................................................................................................
Page 30 - IOM / ROOFTOP BALTIC Series - 0803 - E
L1 ........A
L2 ........A
L1 ........A
L2 ........A
L1 ........A
L2 ........A
L1 ........A
L2 ........A
L1 ........A
L2 ........A
L1 ........A
L2 ........A
Phase 2
Phase 3
Suction/ Asp
........ A
........ A
........ A
........ A
........ A
........ A
........ A
........ A
Valve1/Vanne1: Yes/Oui
Valve2/Vanne2: Yes/Oui
Phase 2
Phase 3
Suction/ Asp
........ A
........ A
........ A
........ A
........ A
........ A
........ A
........ A
......Bar
LP cut out / Coupure sécurité BP
C1 : ...........kg
er
étage (Baltic)
3 ...................
Valve type / Type vanne:
.........................
Gas type / Type gas : G.......
Drop test / test pression
Yes/Oui
No/ Non
CO2 %:
CO ppm:
.........%
.........%
Sensor type / Type Capteur:
................................
Check Rotation
L3 ......A
Yes/Oui
L3 ......A
Yes/Oui
L3 ......A
Yes/Oui
L3 ......A
Yes/Oui
L3 ......A
Yes/Oui
L3 ......A
Yes/Oui
Pressures & Temperatures / Pressions & températures
Temperatures / Temperatures
Disch / refoul
......... °C
......... °C
......... °C
......... °C
......... °C
......... °C
......... °C
......... °C
No/ Non
No/ Non
Pressures & Temperatures / Pressions & températures
Temperatures / Temperatures
Disch / refoul
......... °C
......... °C
......... °C
......... °C
......... °C
......... °C
......... °C
......... °C
C2 : ...........kg
Serial No/ No Série.:.............................
nd
AMPS 2
stage (Baltic) / Intensité 2
1 ...................
Gas Burner N°2 / Brûleur gaz N°2
Size / Taille:
............................
Pipe size/ tuyauterie
line press./ press. ligne :
...........................
Check manifold pressure/ Pression injection:
High fire/Grande allure............. Low fire/Petite allure...........
Pressure cut out airflow press switch / Pression coupure
pressostat débit d'air : ........................mbar /Pa
Motor Amps
I Moteur:
temp fumées
..........A
KP07 KP/17 checked/ vérifiées:
Yes/Oui
No/ Non
Compressor
Voltage/ Tension
No/ Non
Compresseur.
No/ Non
No/ Non
Comp1: ........ V
No/ Non
Comp2: ........ V
No/ Non
Comp3: ........ V
No/ Non
Comp4: ........ V
Pressures / Pressions
LP/ BP
......... Bar
......... Bar
......... Bar
......... Bar
Valve3/Vanne3: Yes/Oui
Valve4/Vanne4: Yes/Oui
Pressures / Pressions
LP/ BP
......... Bar
......... Bar
......... Bar
......... Bar
................. Bar
C3 : ...........kg
e
étage (Baltic)
2 ...................
3 ...................
No/ Non
Valve type / Type vanne:
.........................
Gas type / Type gas : G.......
Drop test / test pression
Yes/Oui
Flue temp /
CO2 %:
.......... °C
.........%
Interconnect wiring checked:
Yes/Oui
HP / HP
......... Bar
......... Bar
......... Bar
......... Bar
No/ Non
No/ Non
HP / HP
......... Bar
......... Bar
......... Bar
......... Bar
C4 : ...........kg
No/ Non
CO ppm:
.........%
No/ Non