Operation; Distance To Wet Areas; Start The Pump - Xylem Flygt 3201 Installation Operation & Maintenance

Table of Contents

Advertisement

Operation

Distance to wet areas

Electrical Hazard:
Risk of electrical shock when pumping or mixing near a lake, jetties, beaches, ponds,
fountains, or similar. There must be a safety distance of at least 20 m (65 ft.) between the
person and the product if the person is in contact with the pumped or mixed liquid.

Start the pump

WARNING:
• If you need to work on the pump, make sure that it is isolated from the power supply and
cannot be energized.
• Make sure that the pump cannot roll or fall over and injure people or damage property.
• In some installations, the pump and the surrounding liquid may be hot. Bear in mind the
risk of burn injuries.
• Make sure nobody is close to the pump when it is started. The pump will jerk in the
opposite direction of the impeller rotation.
NOTICE:
Make sure that the rotation of the impeller is correct. For more information, see Check the
impeller rotation.
1. Check the oil level in the oil housing.
2. Remove the fuses or open the circuit breaker, and check that the impeller can be
rotated freely.
3. Conduct insulation test phase to ground. To pass, the value must exceed 5 megohms.
4. Check that the monitoring equipment works.
5. Start the pump.