5-4
Use the DeviceNet Test Application for 1784-PCIDS Diagnostics
This hexadecimal
number is the
count in bytes.

Write Outputs

Write Outputs lets you write as many as 2048 bytes to the output image table of the
scanner using manual data entry in a dialog box. The scanner must be in Run Mode
for writes to be seen at the output device.
1. Select the desired byte(s).
2. Type in the desired value(s).
3. Press the Write button. The transfer is performed.

Use the Device Status Screen

The Device Status screen displays an Idle/Failure Table where you can double-click
on a node to see its status, i.e., MAC ID, status code, and status info, e.g., device
stopped communicating.
If you double-click on an empty node, you see the response, "OK or not in scan
list."