Troubleshooting
Initial Power Up
Apply power with door closed.
Relays click.
Which display is shown?
MICRO DEFR WARM MEDHI POWER HOLD
Proceed to "Standby" condition.
YES
TIMER
READY
COOK
CLOCK
LEVEL
1.
Open line fuse.
Open cavity TCO.
2.
NO
3.
Inoperative control board.
4.
Broken or improper wire connections.
5. Open magnetron TCO (only on models
P1323013M thru P1323017M).
MICRO DEFR WARM MEDHI POWER HOLD
Blower, oven light, and antenna
all activate.
1.
Open magnetron TCO (only on models
P1323003M thru P1323009M).
2.
Inoperative interlock switch assembly (logic).
3.
Broken or improper wire connections.
23
TIMER
READY
COOK
CLOCK
LEVEL
RS2240002 Rev. 1