Test Modes

Power Test (Traditional Test Method)
Test equipment required is Amana power test kit R0157397 (Fahrenheit), or
Menumaster power test kit M95D5 (Celsius).
1. Fill the plastic container to the 1000 ml. line with cool tap water.
2. Using the thermometer; stir the water, measure, and record the water temperature.
Initial water temperature should be approximately 60°F (16°C).
3. Place container on the center of the oven shelf and heat the water for
33 seconds for ovens with more than 1550 watts or 63 seconds for ovens with less than 1550 watts.
NOTE: Use a watch second hand, not the oven timer.
4. Stir the water, measure and record the temperature of the water after heating time is complete.
5. Subtract the starting water temperature (Step 2), from the ending water temperature (Step 4) to obtain the
temperature rise (DT).
6. See the Traditional Power Test Temperature Chart below.
NOTES: • The IEC-705 test method requires precision measurements and equipment. It is not practical to
perform the IEC test in the field. To convert the traditional power test results to the approximate IEC-
705 rating, take the traditional power test results and add 100 watts per magnetron for the unit being
tested.
Example: 1627
+ 200
1827
• Always perform power test three times for accuracy, changing the water after each test is performed.
• Variation or errors in the test procedure will cause a variance in the temperature rise. Additional power
tests should be made if temperature rise appears marginal.
• Low line voltage will cause lower temperature rise.
ONE MINUTE, THREE SECONDS run time chart for units less than 1550 watts cooking power.
∆ ∆ ∆ ∆ ∆ T
Cooking
(°F)
Power Output
16
620
17
659
18
697
19
736
20
775
21
814
22
852
23
891
24
930
25
969
THIRTY THREE SECONDS run time chart for units more than 1550 watts cooking power.
∆ ∆ ∆ ∆ ∆ T
Cooking
(°F)
Power Output
20
1550
21
1627
22
1705
23
1782
24
1860
watts output using the traditional power test for model HDC18
watts (2 magnetrons X 100 watts)
Approximate IEC-705 results
Temperature Chart
∆ ∆ ∆ ∆ ∆ T
Cooking
(°F)
Power Output
26
1007
27
1046
28
1085
29
1124
30
1162
31
1201
32
1240
33
1279
34
1317
∆ ∆ ∆ ∆ ∆ T
Cooking
(°F)
Power Output
25
1937
26
2015
27
2092
28
2170
29
2247
∆ ∆ ∆ ∆ ∆ T
Cooking
(°C)
Power Output
7
490
8
560
9
630
10
700
11
770
12
840
13
910
14
980
∆ ∆ ∆ ∆ ∆ T
Cooking
(°C)
Power Output
11
1540
11.5
1610
12
1680
12.5
1750
13
1820
13.5
1890
21
∆ ∆ ∆ ∆ ∆ T
Cooking
(°C)
Power Output
15
1050
16
1120
17
1190
18
1260
19
1330
20
1400
21
1470
22
1540
∆ ∆ ∆ ∆ ∆ T
Cooking
(°C)
Power Output
14
1960
14.5
2030
15
2100
15.5
2170
16
2240