Type code

The type code of the drive is indicated on the type designation label, attached on the
supply cubicle door. The type code contains information on the specifications and
configuration of the drive. The first digits from left express the basic configuration
(e.g. ACS800-07-0610-3). The optional selections are given thereafter, separated by
+ signs (e.g. +E202). The main selections are described below.
Note: The information below is for quick reference only and does not contain all
conditions and details. For more information, refer to ACS800 Ordering Information
(code: 64556568), available through ABB representatives.
Selection
Product series
Type
Size
Voltage range
(nominal rating in bold)
+ options
I/O options
Fieldbus adapter
Application program
Degree of protection
Construction
Filters
Resistor braking
Hardware description
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Alternatives
ACS800 product series
07 = cabinet-mounted
When no options are selected: IP21 (UL Type 1), main switch/
disconnector(s), 230 V auxiliary voltage, du/dt filtering (+E205), common
mode filtering (CMF) (+E208), EMC/RFI filtering for second environment
(+E210), Standard Application Program, bottom entry/exit of cables,
coated circuit boards, set of English manuals.
Refer to Technical data: Ratings.
3 = 380/400/415 VAC
5 = 380/400/415/440/460/480/500 VAC
7 = 525/575/600/690 VAC
Refer to ACS800 Ordering Information (3AFY64556568 [English]).
B053 = IP22 (UL Type 1)
B054 = IP42 (UL Type 1)
B055 = IP54 (UL Type 12) (Not available with +C134)
B059 = IP54R (with connection to air outlet duct)
C121 = Marine construction (reinforced mechanical parts and fastening,
marking of conductors [A1], door handles, self-extinctive materials)
C129 = UL Listed (115 V AC auxiliary voltage, cable conduit entries, all
components UL listed/recognized, max. supply voltage 600 V; +F253,
+F260 and top entry of cables are standard)
C134 = CSA Approved (as +C129, with CSA approved components)
E202 = EMC/RFI filtering for first environment TN (grounded) system,
restricted (A-limits). Only for 6-pulse ACS800-07-0610-3 and -0760-5.
Requires +F253 and +F260.
E206 = Sine output filters (Not available with +C121, +C129 or +C134)
Note: du/dt filtering (+E205), common mode filtering (CMF) (+E208), and
EMC/RFI filtering for second environment (+E210) are standard
equipment.
D150 = brake choppers
D151 = brake resistors (not available in IP54 or IP54R)