Output specifications

Item
Rated output voltage
*1
Output voltage range
Continuous rated
output 204 W
Continuous rated
output 330 W
*2
Peak output
Default initial voltage
Ripple voltage
Ripple noise voltage
Startup time
Output retention time
*1: In order to enable parallel operation, this power supply can vary the output voltage according
to the load. Therefore, the power supply unit is dedicated for IAI controllers. Refer to "Output
voltage" on page 4-1 for the characteristics of output voltage by load.
*2: Peak output conditions are as follows.
· Peak current duty cycle is within 30%
D ≤
0.3
· Peak current energization time is within 10 seconds
t ≤
10[sec]
· The average current is within the continuous rated current value I
derating (See Figure 2.1.1 for derating)
2
2
(I
D)
(I
×
+
I
P
I
m
t
T
Figure 1.2.1 Peak output power conditions
Specifications
24 V
24V ±10%
8.5A
13.8A
17A (408W)
25.5V (typ)
0°C~70°C
120mV or less
10°C~0°C
160mV or less
0°C~70°C
150mV or less
10°C~0°C
180mV or less
2 seconds or less
20 ms or more
12ms or more
(1-D))
×
I
0
D = Duty cycle t/T
t
= Peak current pulse width
T = Cycle
Ip = Peak current value
Im = Minimum current value
Io = Rated current value specified in the Rated
1.2 General Specifications
Terms of use, etc.
Without fan
With fan
No load
0A ~ 13.8A
0A ~ 13.8A
Rated input / continuous rated output 330 W
Rated input / continuous rated output 204 W
Rated input / continuous rated output 330 W
defined by rated output
O
1-4