Download Print this page

IAI PSA-24 First Step Manual

24v
Hide thumbs Also See for PSA-24:

Advertisement

Quick Links

PSA-24/PSA-24L
(24V Power Supply)
First Step Guide
Second Edition
Thank you for purchasing our product.
Make sure to read the Safety Guide and detailed Instruction Manual (DVD) included with the product in addition to
this First Step Guide to ensure correct use.
This Instruction Manual is original.
Warning : Operation of this equipment requires detailed installation and operation instructions which are
provided on the DVD Manual included in the box this device was packaged in. It should be retained
with this device at all times.
A copy of the Manual can be requested by contacting your nearest IAI Sales Office listed at the
back cover of the Instruction Manual or on the First Step Guide.
 Using or copying all or part of this Instruction Manual without permission is prohibited.
 The company names, names of products and trademarks of each company shown in the sentences are registered
trademarks.
Caution in Handling
● PSA-24/PSA-24L Power Supplies are the power supply units dedicated for IAI
controllers of the 24V DC type.
● Do not attempt to connect in parallel several power supply units in different
capacities. Do not attempt to connect PSA-24 (without fan), PSA-24L (with fan)
and PS-24 in parallel. Connect PSA-24 with only PSA-24, or PSA-24L only with
PSA-24L in parallel.
Product Check
This product is comprised of the following parts if it is of standard configuration.
If you find any fault in the contained model or any missing parts, contact us or our distributor.
1. Parts (The option is excluded.)
No.
Part Name
1
24V Power Supply Main Unit
Refer to "2. How to read the model plate", "3. How
to read the model No."
Accessories
2
First Step Guide (This Manual)
ME0380
3
Instruction Manual (DVD)
4
Safety Guide
M0194
2. How to read the model plate
PSA-24
Model
Serial No.
Rated Input
Rated Output
PSA-24L
Model
Serial No.
Rated Input
Rated Output
3. How to read the model No.
P S A - 2 4 - L
<Fan-Equipped Option>
No Description : Standard Type (204W)
L
: Fan-Equipped Type (330W)
<Type>
24
: 24V power supply
FU
: Fan Unit (Unit Itself)
* Condition of Use for PSA-24 External Fan
When forced air cooling is to be conducted, follow the condition when certified by UL.
As an option to follow the condition when certified by UL, there is PSA-FU.
4. Instruction manuals related to this product, which are contained in the instruction
2A
manual (DVD)
No.
1
PSA-24/PSA-24L (24V Power Supply) Instruction Manual
Specifications
Specification Item
Rated Voltage DC Output
Rated DC Current Output
Peak Maximum DC
Current Output
Rated Output Wattage
Efficiency
Rated Input Voltage
(frequency)
Input Current
Output Holding Time
Protection Circuit
Parallel Operation
Operation Ambient
Temp.
Operation Ambient
Humidity
Cooling Method
Voltage Durability
Insulation Strength
Altitude
Overvoltage Category
Pollution Level
Installation Area
Circuit System
Mass
Model
Do not use this product in the following environment.
• Location where the surrounding air temperature exceeds the range of 0 to 55°C
• Location where condensation occurs due to abrupt temperature changes
• Relative humidity greater than 85%RH
• Location exposed to corrosive gases or combustible gases
• Location exposed to significant amount of dust, salt or iron powder
• Location subject to direct vibration or impact
• Location exposed to direct sunlight
• Location where the product may come in contact with water, oil or chemical droplets
When using the product in any of the locations specified below, provide a
sufficient shield.
• Location subject to electrostatic noise
• Location where high electrical or magnetic field is present
• Location with the mains or power lines passing nearby
Installation and Noise Elimination
1. Grounding
Name
Manual No.
ME0379
Basic Specifications
PSA-24
PSA-24L
24V±10% (fluctuates depending on duty)
8.5A
13.8A
17A
204W
330W
100V AC : 86%
200V AC : 90%
100V AC to 230V AC ± 10%
[50/60Hz]
100V AC: 2.5A
100V AC : 3.9A
200V AC : 1.4A
200V AC : 1.9A
(Continuous Rated Output 204W)
(Continuous Rated Output 330W)
20ms
12ms
(Continuous Rated Output 204W)
(Continuous Rated Output 330W)
Over current protection, over voltage protection, over temperature protection,
over load protection, Input low voltage, Fan rotation drop
Applicable
0 to 55°C (with derating)
85%RH or less
Natural air-cooling
Forced air cooling
3000V AC 1min. (AC Input - DC Output)
2000V AC 1min. (AC Input - FG)
500V AC 1min. (DC Output - FG)
50M min. at 500V DC
2,000m or less
2
Indoor
LCC Resonant System
805g
845g
Installation Environment
.
2
Heatsink and Mounting Method
In the figures below show the minimum distance between the control panel and walls and
minimum distance among power sources in parallel operation.
Also, make sure to keep the temperature below the ambient temperature specified for the
power source when design and install the control panel.
● PSA-24
● PSA-24L
Direction of air flow for forced air cooling (natural convection)
Caution: The main housing of the product gets so hot that it sometimes gives you a
burn as it works as a heat sink.
Do not touch while the power is on, or even after the power is off until the
heat calms down.

Advertisement

loading

Summary of Contents for IAI PSA-24

  • Page 1 (frequency) [50/60Hz] A copy of the Manual can be requested by contacting your nearest IAI Sales Office listed at the 100V AC: 2.5A 100V AC : 3.9A back cover of the Instruction Manual or on the First Step Guide.
  • Page 2 Name and Function of Each Part Set up the slave address assignment in communication for when connecting multiple power sources in multi-drop wiring and monitoring the status by communication. ● PSA-24 Switch Names : DRR7016C (NIDEC COPAL ELECTRONICS CORPORATION) Item Description Initial Setting “0”...
  • Page 3 D ≤ 0.3 overload detection inside should be compulsorily switched to the setting for PSA-24 ● The communication time of the peak current should be 10 seconds or less.

This manual is also suitable for:

Psa-24l