Data - Mitsubishi Electric PUHZ-SW50VHA Service Manual

Split-type, air to water heat pump
Hide thumbs Also See for PUHZ-SW50VHA:
Table of Contents

Advertisement

5

DATA

5-1. REFILLING REFRIGERANT CHARGE (R410A: kg)
Service Ref.
PUHZ-SW40VHA
PUHZ-SW40VHA-BS
PUHZ-SW40VHAR1
PUHZ-SW40VHAR1-BS
PUHZ-SW50VHA
PUHZ-SW50VHA-BS
PUHZ-SW50VHAR1
PUHZ-SW50VHAR1-BS
PUHZ-SW50VKA
PUHZ-SW50VKA-BS
5-2. COMPRESSOR TECHNICAL DATA
PUHZ-SW40VHA(-BS)
PUHZ-SW40VHAR1(-BS)
Service Ref.
PUHZ-SW50VHA(-BS)
PUHZ-SW50VHAR1(-BS)
Compressor model
SNB130FGCM2
U-V
Winding
U-W
Resistance
( " )
W-V
OCH525C
10 m
20 m
30 m
2.1
2.3
2.1
2.3
1.4
1.6
Additional charge is required for pipes
longer than 10 m.
PUHZ-SW50VKA(-BS)
SNB130FTCM2
0.64
0.64
0.64
0.64
0.64
0.64
Piping length (one way)
40 m
50 m
2.5
2.7
2.5
2.7
1.8
2.0
(at 20°C)
10
Initial
charged
60 m
75 m
2.1
2.1
1.4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents