4.2 Connections overview

1. Alternate power connector
2. Network / PoE connector
The alternate power connector is required when
connecting to a network which does not support
Power over Ethernet PoE. The alternate power
connector must be connected directly to a power
supply.
Note: Do not connect the alternate power
connector to a SeaTalk
Note: Only use one power source. There is no
need to connect the alternate power connector
when the keypad is being supplied PoE.
Cables and connections
ng
network.
4.3 Alternate power connection
When the keypad is not supplied Power over
Ethernet (PoE) then the alternate power connection
should be connected directly to a 12 V dc or 24 V dc
power supply.
1. Keypad
2. Right angled power cable
3. Black negative wire
4. Ground / shield wire
5. Red positive wire
Warning: Product grounding
Before applying power to this product,
ensure it has been correctly grounded, in
accordance with the instructions provided.
Grounding — Dedicated drain wire
The power cable supplied with this product includes
a dedicated shield (drain) wire for connection to a
vessel's RF ground point.
It is important that an effective RF ground is
connected to the system. A single ground point
should be used for all equipment. The unit can be
grounded by connecting the shield (drain) wire of
the power cable to the vessel's RF ground point.
On vessels without an RF ground system the shield
(drain) wire should be connected directly to the
negative battery terminal.
The dc power system should be either:
• Negative grounded, with the negative battery
terminal connected to the vessel's ground.
• Floating, with neither battery terminal connected
to the vessel's ground
Warning: Positive ground
systems
Do not connect this unit to a system which
has positive grounding.