Indicator Lamps: There are 6 indicator lamps located on the unit control panel:
(amber lamp): When lit, indicates power is applied to the unit.
Power
(green lamp): When lit, indicates normal water flow.
Water Flow
Heat Demand
target water temperature.
Compressor Delay Active
compressor anti-short cycle timer is active. The fan will run but the compressor will be
OFF for 6 to 8 minutes.
Defrost Active
when ice starts to form on the outside coil. The fan will continue to run but the compressor
will stay OFF (not heating) until weather conditions improve.
Low Pressure
lamp is ON, service is required. Call the number shown in the CONTACT INFORMATION
at the front of this manual.
V. Initial Start-Up and Check
1. Verify that the
Power
2. Verify that the control panel
the figure.
3. Turn the control switch to either
setting above the current water temperature. At this time the 2 green lamps should illuminate.
The fan and compressor should start up and run simultaneously.
Control panel
Indicator lamps
(green lamp): When lit, indicates the actual water temperature is below the
(amber lamp): Under normal operation, when lit, indicates
(red lamp): When lit, indicates unit is in defrost mode. Defrost mode occurs
(red lamp): When lit, indicates failure in the refrigeration circuit. When this
lamp is ON and that the pool pump is running and circulating properly.
Spa-Remote-Pool
Pool
When any combination
of these 5 lamps is lit,
operation is normal.
switch is in the
or
to turn the system ON and raise the thermostat
Spa
4
When this
lamp is lit,
unit requires
service.
(OFF) position; see
Remote