4.10 Memories

The time will probably come when you will want to store settings for repetitive testing of
equipment. The COM3010 memory is broken down into Sequences that contain Registers. A
Sequence can be assigned to each different piece of equipment you test. The registers in that
sequence can contain all the test set-ups needed for that specific piece of equipment. A
register will store most items on the display except for sweep setups.
The registers in a sequence can be used to store all test setups for a particular type of
equipment, and the
When the last saved register in a sequence has been reached, another push of the
will loop the user back to the first register. This is useful when performing identical tests on
multiple units.
The COM3010 provides safeguards that allow for ease of use and prevent accidentally
overwriting another memory location. For example, when saving a register to a sequence that
has memories stored in it, the COM3010 will select the first empty register available. The
Property of Ramsey Electronics, Inc.
only exception occurs when the sequence contains the maximum 100 registers, or is full. In
this situation the COM3010 will select register 00 and give the operator the option of
overwriting this register.
Do not reproduce or distribute.
100 Sequences are available, and 100 Registers can be stored in each Sequence. Sequences
and registers are displayed on the GENERATE screen in the lower right corner.
GENERATE
Modulation
Saving to Memory
1.
Enter all the information into the COM3010 that you need. This should include:
Generate and Receive Frequencies, RF and Modulation levels, Increment sizes, and
Meter Set-ups.
2.
Press
3.
Select a two digit Sequence Number. Example: 02
4.
The COM3010 automatically jumps to the Register field and selects the first empty
register in that sequence.
5.
If this sequence is full it will loop back to "00" and overwrite that register.
6.
If you do not wish to overwrite, cancel by pressing
7.
Press
to save.
UP/DOWN
arrows can be used to move through each test in a series.
TX Level
Seq/Reg