Welding Capability; Meaning Of Graphical Symbols On Case Front - Lincoln Electric DC-600 series Operator's Manual

Multi-process welders
Table of Contents

Advertisement

B-3

WELDING CAPABILITY

The DC-600 has the following Output and Duty Cycle
based on operation for a 10 minute period:
600 Amps, 44 Volts at 100%
680 Amps, 44 Volts at 60%
750 Amps, 44 Volts at 50%
MEANINGS OF GRAPHICAL SYMBOLS ON CASE FRONT
Input POWER ON/OFF Switch
SYMBOL
Pilot Light
Input power on when light is illuminated
(except for abnormal conditions).
Always indicates POWER ON/OFF
switch is in ON position.
OUTPUT CONTROL
Clockwise Increase of Output
TERMINALS ON/REMOTE Switch
Remote Control of Output Terminals
(Energized or Non-Energized)
OPERATION
MEANING
ON
OFF
INPUT POWER
OUTPUT VOLTAGE
AND CURRENT
Voltage and Current
OUTPUT TERMINALS
ENERGIZED
LOCAL/REMOTE Switch
SYMBOL
Current is Via DC-600's Control Dial
Remote Control of Output Voltage
MODE Switch
Output Terminal Connections
WARNING Identification
Circuit Breaker
DC-600
MEANING
Control Of Output Voltage and
and Current
CC STICK: Shielded Metal Arc
Welding (SMAW), this switch
position is also used for Air
Carbon Arc Cutting (AAC)
CV SUBMERGED ARC:
Constant Voltage Submerged
Arc Welding (SAW)
CV INNERSHIELD: Flux Cored
Arc Welding (FCAW), this switch
position is also used for Gas
Metal Arc Welding (GMAW).
Positive Output Terminal
Negative Output Terminal
Warning Identification
Circuit Breaker (two breakers: 15A
for 115V circuit and 10A for 42V
circuit)
B-3