Summary of Contents for Lincoln Electric IDEALARC DC-600
Page 1
IDEALARC DC-600 SAFETY DEPENDS ON YOU Lincoln Electric welders are designed and built with safety in mind. However, your overall safety can be increased by proper installation and thoughtful operation on your part. Read and observe the general safety precautions on page 2 and follow specific installation and operating instructions included in this manual.
PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. READ AND UNDERSTAND BOTH THE SPECIFIC INFORMATION GIVEN IN THE OPERATING MANUAL FOR THE WELDER AND/OR OTHER EQUIPMENT TO BE USED AS WELL AS THE FOLLOWING GENERAL INFORMATION. ARC WELDING SAFETY PRECAUTIONS ARC RAYS can burn ELECTRIC SHOCK can kill 1.
Page 3
3. Should the primary cord be damaged, a special cord is required, and is available from Lincoln Electric. 4. Parts should be ordered from Lincoln, its offices or the nearest Authorised Service Facilities. (The “Lincoln Service Directory”...
That welder and his or her pacemaker may be quite practice to eliminate a common problem on welding - a different from you and your pacemaker. poor work connection. • Do not work next to the welding power source. Page 4 Idealarc DC-600 IMA 607A...
Maintenance of the Welding Equipment Products are: The welding equipment should be routinely maintained according • for use with other Lincoln Electric/LiquidArc equipment. to the manufacturer’s recommendations. All access and service • designed for industrial and professional use. doors and covers should be closed and properly fastened when Introduction the welding equipment is in operation.
Figure A.1 Stacking Idealarc DC-600 machines STACKING HOLE STACKING PINS TILTING The Idealarc DC-600 must be placed on a stable, level surface so it will not topple over. IMA 607A Idealarc DC-600 Page 7...
For 200 Voltage, see Figure A.4. (AT3164-11). For 380/550/575, see Figure A.5. (AT3164-12). For Voltages not listed, see the Input Connection Diagram pasted on the inside of the Case Back Input Access Door. Page 8 Idealarc DC-600 IMA 607A...
Page 9
INPUT CONTACTOR THE CRI CONTACTOR AS SHOWN. 4. CONNECT TERMINAL MARKED TO GROUND PER LOCAL AND NATIONAL ELECTRIC CODES. 5. MOUNT THE LINKS IN THE POSITIONS SHOWN WITH THE PROVIDED HEX NUTS. PILOT TRANSF IMA 607A Idealarc DC-600 Page 9...
OUTPUT CONNECTIONS See Table A.1 for recommended IDEALARC DC-600 cable sizes for combined lengths of electrode and work cables. Table A.1 Idealarc DC-600 Cable Sizes for Combined Lengths of Electrode and Work Cable (Copper) at 100% Duty Cycle Cable Length...
OPERATING INSTRUCTIONS WARNING RECOMMENDED PROCESSES AND EQUIPMENT The Idealarc DC-600 is recommended for the following welding or Read and understand entire section before operating machine. cutting processes within its output capacity of 70 amps to 850 amps in the Constant Voltage mode and 90 amps to 850 amps in...
(Based on 10 min) 100% 50/60 CONTROLS AND SETTINGS All operator controls and adjustments are located on the Case Front Assembly of the Idealarc DC-600. See Figure B.1 for the location of each control. Figure B.1 Control Panel Keys 8. AMP FUSE...
OPERATING STEPS SEMI-AUTOMATIC AND AUTOMATIC WIRE FEEDING WITH A IDEALARC DC- The following procedures are for using the Idealarc DC-600 in the local control mode of operation. For remote control of the 600 AND WIRE FEEDERS machine, see the Remote Control of Machine Operation section.
IDEALARC DC-600 POWER SOURCE SETTING WHEN CONNECTED TO NA-5 WIRE FEEDER When using the Idealarc DC-600 with the NA-5 wire feeder, set the controls on the Idealarc DC-600 as follows for the best performance: Turn OFF main AC input power supply to the Idealarc DC- 600.
Follow these steps to install the MULTI-PROCESS SWITCH: Connect the control leads from the MULTI-PROCESS Confirm that the Idealarc DC-600 ON/OFF PUSH BUTTON SWITCH to terminals #2 and #4 on the Idealarc DC-600's is in the OFF position. terminal strip.
Connect the right cable from the MULTI-PROCESS installed, the Idealarc DC-600 lift bail is no longer functional. Do SWITCH (facing the front of the machine) to the Idealarc not attempt to lift the machine with the undercarriage attached. DC-600 positive (+) output terminal. See Figure C.4.
Page 17
To change polarity: c. Keep the # 21 lead electrically separate from the work a. Set the Idealarc DC-600 ON/OFF PUSH BUTTON to cable circuit and connection. OFF. d. Tape the # 21 lead to work cable for ease of use.
Page 18
Note: The Idealarc DC-600 must be properly grounded. Figure C.7 LN-8 or LN-9 Wire Feeder Connectionto the Idealarc DC-600 PERFORM THIS STEP ONLY IF THE LN-7 IS EQUIPPED WITH A METER KIT. LN8 OR LN 9 WIRE FEEDER Extend wire feeder control cable lead #21 so it can be...
Inspect the electrode cables for any slits or punctures in the Note: The fan motor has sealed bearings which require no cable jacket, or any condition that would affect the proper maintenance. operation of the machine. IMA 607A Idealarc DC-600 Page 19...
HOW TO USE TROUBLESHOOTING GUIDE WARNING Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel. Unauthorised repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical Shock, please observe all safety notes and precautions detailed throughout this manual.
If the P.C. Board uses protective shorting jumpers, don’t remove them until installation is complete. If you return a P.C. Board to The Lincoln Electric Sometimes machine failures appear to be due to PC board Company for credit, it must be in the static-shielding failures.
(SYMPTOMS) MISADJUSTMENT(S) COURSE OF ACTION OUTPUT PROBLEMS Major Physical or Electrical Contact the Lincoln Electric Service Damage is Evident The machine is dead - the Input 1. Check for blown or missing fuses contactor does not operate. in input lines.
Page 24
If the problem disappears the fault is in the control cable or wire feeder. 2. If some open circuit voltage is present (over 3VDC) after performing Step #1, then the problem is within the DC-600. Page 24 Idealarc DC-600 IMA 607A...
Lincoln Authorised Field Service the DC-600. Facility 2. Make sure the proper welding procedures are being used (wire feed speed, arc voltage and wire size). 3. Check the welding cables for loose or faulty connections. IMA 607A Idealarc DC-600 Page 25...
Page 26
Figure D.1 General Assembly Exploded View Page 26 Idealarc DC-600 IMA 607A...
Page 30
AP-216-C Operative: May 2003 Supersedes: Case Front Panel Assembly (Control Box Assembly shown) Page 30 Idealarc DC-600 IMA 607A...
Page 31
This will aid Lincoln in supplying the correct and latest board along with any necessary jumpers or adapters. The dash number brackets [ ] have purposely been left blank so as to eliminate errors, confusion and updates. IMA 607A Idealarc DC-600 Page 31...
Page 32
AP-216-D Operative: May 2003 Supersedes: Control Box Assembly (Case Front Panel Assembly shown) Page 32 Idealarc DC-600 IMA 607A...
Page 33
14 pin Amphenol Plug Base (code 1548 & above) S12021-40 Box Connector T9639-1 Plug Button T13597-1 Number Plate AS4236 Door and Welded Assembly S17750 Self Tapping Screw S8025-71 Decal T13260-3 Terminal Strip S8542-7 Self Tapping Screw S8025-15 IMA 607A Idealarc DC-600 Page 33...
Page 34
AP-216-E Operative: May 2003 Supersedes: Case Rear Panel Assembly Page 34 Idealarc DC-600 IMA 607A...
Briggs & Stratton for 5 years. CUSTOMER ASSISTANCE POLICY service dealer). The business of The Lincoln Electric Company is manufacturing and selling high quality Kubota Engines and Accessories *Subject to conditions welding equipment, consumables, and cutting equipment. Our challenge is to meet the (Warranty service can only be carried out an imposed by Kubota.