ProsKit MT-5110 User Manual

ProsKit MT-5110 User Manual

3 1/2 capacitance meter

Advertisement

MT-5110 3 1/2 Capacitance Meter
User's Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MT-5110 and is the answer not in the manual?

Questions and answers

Omar
March 10, 2025

Puedo medir tensión **** las puntas

1 comments:
Mr. Anderson
March 10, 2025

No, the ProsKit MT-5110 cannot measure voltage. According to the provided information, its max AC voltage and max DC voltage are both 0V, meaning it does not support voltage measurement.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for ProsKit MT-5110

  • Page 1 MT-5110 3 1/2 Capacitance Meter User’s Manual...
  • Page 2: Specifications

    1. FEATURES Easy and correct readout. High measuring accuracy. Measurements are possible even under a strong magnetic field. LSI-circuit provides high reliability and durability. Input overload protection is provided. LCD display for low power consumption and clear readout even in bright ambient light conditions.
  • Page 3: Electrical Specification

    2-2. ELECTRICAL SPECIFICATION Accuracy is (percentage of reading + number of digit) at 23 5 ,<80%RH. Test Max indication Range Accuracy Resolution Frequency value 200pF (0.5%+7) 0.1pF 800Hz 199.9pF 800Hz 1.999nF 20nF 10pF 800Hz 19.99nF 200nF 100pF 800Hz 199.9nF (0.5%+5) 1000pF 800Hz 1.999uF...
  • Page 4: Capacitance(C) Measuring Procedure

    When measuring components within circuit that circuit must be switched off and de-energized before connecting the test leads. Do not close (black & red) test leads. Instruments used in dusty environments should be stripped and cleaned periodically. Do not leave the instrument exposed to direct heat from the sun for long periods.
  • Page 5: Maintenance

    short leads in order to avoid introducing any stray inductance. (d) When using the optioned test leads, remember that the leads introduce a measurable capacitance to the measurement. As a first approximation, the test lead capacitance may be measured by opening the leads at the trips, recording the open circuit value and subtracting that value.
  • Page 6 MT-5110 3 1/2 2-1. LCD( 1999 0.1pF to 20000uF ±20pF) “1” 0 ~5second 0 ℃ ~40 ℃ . 80%.R.H. NEDA 1604IEC 6F 22 200pF - 200uF...
  • Page 7 2-2. ± 23 ± 5℃ <80 ±(0.5%+7) 200pF 0.1pF 800Hz 199.9pF 800Hz 1.999nF 20nF 10pF 800Hz 19.99nF 200nF 100pF 800Hz 199.9nF ±(0.5%+5) 1000pF 800Hz 1.999uF 20uF 0.01uF 80Hz 19.99uF 200uF 0.1uF 199.9uF 2000uF ±(2%+5) 1999uF 20000uF ±(3%+10) 10uF 1999(×10)uF pF= Pico Farad(10 F ) nF= nan Farad(10 F).
  • Page 8 “ - ” +” “0” 200pF 2nF 20nF “0” (pF, nF, uF) “1” 200pF 200pF...
  • Page 9 1) 9 5×20mm, 200mA/250V...
  • Page 10 ©2011 Prokit’s Industries Co., LTD. All rights reserved 2011001(T)

Table of Contents