CM050B
The CP050B Night Arm Station allows you to arm and disarm the system in either PART Mode 1 or PART Mode 2
by simply pressing a single button. Arming in PART Mode automatically disables all zones that you do not wish to
detect intrusion (e.g. Bedrooms, living rooms etc).
PART Mode is ideally used at night when you want only the perimeter of the premises to be in a ready state to
detect intrusion and at the same time allow you to move freely within an area without causing an alarm condition.
Zones that are to be disabled in PART Mode 1 are programmed by the installer and zones which are to be disabled
in PART Mode 2 are programmed by the master user.
If an emergency situation arises, the Night Arm Station will allow you to initiate an audible panic alarm. To trigger
a panic alarm, both the PART 1 and PART 2 buttons need to be held down simultaneously for at least two seconds.
The system sirens and strobes will activate and can only be deactivated by entering a valid user code via the keypad.
A panic alarm can be activated at any time whether or not the system is already armed.

Operation

Arming and Disarming in PART Mode 1 and 2
With the system in the disarmed state (OK indicator illuminated or flashing), press the PART 1 button on the Night
Arm Station once to arm the system in PART Mode 1 (ON indicator illuminated). To turn PART Mode 1 OFF, press the
PART 1 button again and the system will disarm.
If the entry warning timer is running or an alarm condition occurs while the system was in either PART mode, you
will not be able to disarm the system using the Night Arm Station. You will need to enter a valid user code at the
keypad.
To arm in PART Mode 2, follow the same procedure as above however press the PART 2 Mode button.