Technical Data - Janfire Integral 25 Installation Manual

Pellet boiler
Table of Contents

Advertisement

2

Technical Data

Janfire Pellet Boiler
Power
Load
Measurement accuracy of water
temperature sensor
Min Return Water temperature
Output
Boiler class according to EN 303-5 4.4.2
Relay output
Fuse
Water tank volume
Water resistance 10K/20K
Max operating pressure
Water resistance at 10 K difference
between flow and return line
Water resistance at 20 K difference
between flow and return line
Ash/fire box
Weight
Boiler type
Hot water
Flue connection
Convection part
Operation thermostat
Flue gas thermometer
Sweeping handle
Shunt
Control panel
Safety cut-out
Required Draft in furnace
Exhaust Temperature Nominal/min load
Combustion period
Fuel
Noise emission
IA 32580002 EN_Ver5
Installation Instructions Janfire Pellet Boiler Integral Typ 25
230 V AC ± 10 %, 50 Hz
3 VA
0– 100° C ± 1° C
55 ° C
23 kW
Class 5
5 A 250 V AC
5A T
180 litres
25,3/14,1 mbar
3 bar
25,3 mbar
14,1 mbar
100 litres
280 kg
Nor condensing, negative pressure controlled
High efficiency heat exchange coil C22 mm
L=11m OBS Option
Backwards Ø 150 mm
Vertical tubes
Adjustable intervals up to 15 ° C
Option
Automatic controlled
Option Mounted on Hot Water Flange
With buttons
Mounted on the top of the door
-10 pascal
145/73° C
Cleaning manual after use of 6 ton pellets
Wood pellets EN 14961-2 Class A1 Ø 6-12 mm
61 db
© Janfire 2014
)