Fujitsu Waterstage WOYG112LCTA Maintenance Document page 54

Air to water heat pump split integrated dhw type
Hide thumbs Also See for Waterstage WOYG112LCTA:
Table of Contents

Advertisement

Air to Water Heat Pump (Split integrated DHW type)
Line
Function
Heat pump (HP)
2803
S
Overrun time cond pump
2843
S
Compressor off time min
2844
S
Switch-off temp max
2862
S
Locking time stage 2 / mod
S
2873
Compressor mod run time
2882
S
Release integr electric flow
2884
S
Release el flow below OT
Electrical release - start-up with outdoor
temperature
2916
S
Max setpoint HP DHW charg
2920
S
With electrical utility lock (EX1)
Released : HP = ON _ Back-up DHW = off _ 1st back-up HP = off _ 2nd back-up HP = off _ Boiler = ON
Locked (Blocked on standby) : HP = off _ Back-up DHW = off _ 1st back-up HP = off _ 2nd back-up HP = off _
Boiler = ON
Energy meter
3113
U
Amount of gas brought in
Cumulation of total consumed electrical energy.
Electrical energy consumed = Electrical energy absorbed by outdoor unit + electric energy absorbed by the heating
electrical backup and / or DHW electrical backup (if installed).
3124
U
Energy brought in heating 1 (N - 1)
3125
U
Energy brought in DHW 1
3126
U
Energy brought in cooling 1
U
3131
Energy brought in heating 2 (N - 2)
3132
U
Energy brought in DHW 2
3133
U
Energy brought in cooling 2
3138
U
Energy brought in heating 3 (N - 3)
U
3139
Energy brought in DHW 3
3140
U
Energy brought in cooling 3
3145
U
Energy brought in heating 4 (N - 4)
3146
U
Energy brought in DHW 4
U
3147
Energy brought in cooling 4
3152
U
Energy brought in heating 5 (N - 5)
3153
U
Energy brought in DHW 5
3154
U
Energy brought in cooling 5
U
3159
Energy brought in heating 6 (N - 6)
3160
U
Energy brought in DHW 6
3161
U
Energy brought in cooling 6
3166
U
Energy brought in heating 7 (N - 7)
U
3167
Energy brought in DHW 7
3168
U
Energy brought in cooling 7
Note: "Energy" Counters increment as of 1 July each year.
- 54 -
Setting range
or display
8... 240 s
0... 120 min
8
100 °C
0... 40 min
10... 600 s
0... 500 °Cmin
-30... 30 °C
8
80 °C
Locked (Blocked on standby),
Released
Installation and operating manual "1768 - EN"
Setting
Basic
increment
setting
1 s
240s
1 min
8 min
1 °C
75 °C
1 min
5 min
240 s
1 s
1 °Cmin
100 °Cmin
2 °C
60 °C
Released
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Hide quick links:

Advertisement

Table of Contents