Electrical Connections - Hotpoint SX1046LPX Service Information

Mono control electronic multifunction pyrolytic built in single ovens with led door lighting
Table of Contents

Advertisement

Indesit
Company
ELECTRICAL CONNECTION
THESE APPLIANCES MUST BE EARTHED.
These models are supplied with a cable and plug fitted. If the plug or the cable need to be
replaced, follow the details below.
The electrical connection to the mains must be made on the appliance. The power voltage and
frequency are as indicated on the rating plate.
Connecting the power supply cable
To open the terminal board:
Using a screwdriver, press on the tabs situated on each side of the terminal board cover.
Pull open the terminal board cover.
To connect the power supply cable, proceed as follows:
Unscrew the cable clamp screw and the contact screws L-N-6.
Fasten the wires beneath the screwheads using the following colour scheme: Blue (N) Brown (L)
Yellow-Green
Fasten the power supply cable in the corresponding cable clamp and close the cover.
Electrical Connection:
4
2
N
L
You can connect your oven to the system means of a terminal board. Refer to above information for
the minimal cable sections and the calibration of the protective elements according to the connection.
If the appliance is installed with a junction box, an omnipolar circuit breaker - with a minimum contact
opening of 3mm - should be installed between the appliance and the mains.
Power cable supply connection to the electrical mains:
We recommend you use a power supply cable which is long enough to allow you to take the oven out
of its recess in the event of maintenance operations (only use HAR - H 05 - RRF quality cables fitted
with a plug conforming to the regulations in force.
Service Manual UK
N
or
L
10 of 49
Voltage Frequency:
230 V-1+N 50Hz
Supply cable: 3 x 1.5mm