Advertisement

Quick Links

USER MANUAL
Safety Information.......................................................................................................... 3
Specifications.................................................................................................................... 4
Main Power Connection...............................................................................................6
DMX-512 Connection................................................................................................... 6
Installation..........................................................................................................................7
Rigging the Fixture..........................................................................................................8
Main Control Menu.......................................................................................................... 9
DMX Profile........................................................................................................................10
Cleaning & Maintenance..............................................................................................11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ribbon 4371 and is the answer not in the manual?

Questions and answers

Summary of Contents for MegaLite Ribbon 4371

  • Page 1: Table Of Contents

    USER MANUAL Table of Contents Safety Information……………………………………………………………………………………………. 3 Specifications…………………………………………………………………………………………………….. 4 Main Power Connection…………………………………………………………………………………..6 DMX-512 Connection…………………………………………………………………...……………..6 Installation…………………………………………………………………………………………………………..7 Rigging the Fixture…………………………………………………………………………………………….8 Main Control Menu......................9 DMX Profile........................10 Cleaning & Maintenance....................11...
  • Page 3: Table Of Contents Safety Information

    Check that the unit has not been damaged during transport Protection Against Fire 1. Maintain a minimum of 1 foot distance from any type of flame. 3. Replace fuse only with the specified type and rating. 4. Do Not install the unit to close to a heat source. 5.
  • Page 4: Specifications

    Specifications 4371-Color Ribbon 24V Specifications IP Rating: IP 67 16 ’ 4 ” LED Quantity: Red: .59 ” DC24V DC24V Green: Blue: 3.92 ” LED Type: SMD-Tri Colored Voltage: Avg rated Life: 30,000hrs Operating temperature: -40ºc to 80ºc Fastening System: Mounting Clips (included) Led Spacing: .65”...
  • Page 5 Fixture 4357– Color Ribbon Power Extender Mechanical Specifications Connectors: Removable phoenix connectors Power Connection: External power supply bare cable Fastening System: 2 fixture mounting points Fixture Packaged for Shipping Size: 4.75”L x 1.56”W x 1.55”H Size: 6”L x 3”W x 3.5”H Weight: .4 lbs Weight: 1.4 lbs Electrical Specifications...
  • Page 6: Main Power Connection

    Main Power Connection Caution! Do not connect fixture to a dimmer system. The occupation of the connection-cable is as follows coming out of the AC to DC adapter 110V Connection Cable (USA) Cable (EU) DC + Black Black DC - DMX-512 Connection The fixture is equipped with 3 pin XLR Sockets for DMX input and output.
  • Page 7: Installation

    Installation Caution! 1. Each Color Ribbon power supply will only power up to 16.4” of Color Ribbon Installing using Color Ribbon Power Supply Caution! Cable may not be more than 100Ft from Color Ribbon Power Supply 16 ’ 4 ” DMX Controller DMX Output DMX Output...
  • Page 8: Rigging The Fixture

    Installing using Color Ribbon Power Supply & Ribbon Power Signal Extender DMX Controller DMX Output DMX Output DMX Input Caution! Caution! Cable may not be more than 100Ft Cable may not be more than 100Ft Power Supply Power Supply Rigging the fixture Caution! 1.
  • Page 9: Main Control Menu

    Main Control Menu The control board on the fixture base is your interface to access and control all the functions on the unit. Its Dip Switch gives you a code view of the options. The following DATA — will explain each function and its options. DATA + 9 10 DMX 512 IN...
  • Page 10: Dmx Profile

    Testing For testing function do not connect DMX signal cable 9 10 Turn dipswitch 10 to the OFF position. This function will allow you to test the intensity of each color or to set the color ribbon to a specific color. FUNCTION GREEN GREEN...
  • Page 11: Cleaning & Maintenance

    Cleaning and maintenance Installation Maintenance: The operator has to make sure that the unit is operating safely and has the installations and electron- ics checked by an expert every 2 years. The following points have to be considered during the inspection: 1) All screws used for installing the device or part of the device have to be tightly connected and must not be corroded.
  • Page 12 Mega-Lite 5718 Kenwick St San Antonio, TX 78238 Ph 210-684-2600 Fax 210-855-6279 www.mega-lite.com / info@mega-lite.com...

Table of Contents