5 MELSEC FUNCTIONS
The following indicates the correspondences between the MELSEC command in the
"MELSEC-Q/L Programming Manual (Common Instructions)" and the MELSEC
function in this manual.
MELSEC-Q/L Programming Manual (Common Instructions) [MELSEC instruction]
6.1.6
BIN block data comparisons (BKCMP
BKCMP
BKCMP
P
Setting
Data
S1
S2
D
n
[MELSEC function] in this manual
5 - 2
indicates an instruction symbol of
Command
BKCMP
Command
BKCMP
3)
: Data to be compared or head number of the devices where the data to be compared is stored (BIN 16 bits)
S1
: Head number of the devices where the comparison data is stored (BIN 16 bits)
S2
: Head number of the devices where the comparison operation result will be stored (bits)
D
n
: Number of comparison data blocks (BIN 16 bits)
Internal Devices
J
R, ZR
Bit
Word
Bit
8)
, BKCMP
High
Basic
Process
performance
/
D
S1
S2
P
D
S1
S2
4)
5)
6)
\
Zn
U
\G
Word
9)
10)
P)
Redundant Universal
LCPU
1)
.
/
/
/
/
n
n
7)
Constants
Other
2)
K, H
11)
12)