Download Print this page

EVERSPRING SP816 Manual page 3

Outdoor motion detector

Advertisement

Programming
Z-Wave Group
The detector supports either one of two Z-wave Association Groups:
Group 1: Association with 1 Controller node.
Group 2: Association with 4 nodes (i.e. end devices such as smart plugs and other lighting
controllers). This allows the detector to transfer commands directly to end devices without
the participation of the controller. This has the effect that when the detector triggers, all
devices associated with detector will be operated.
Group 1 commands:
 When the unit is powered up and was already a part of a Z-Wave network, the unit will
send a Notification Report to the node in Group 1.
 When the detector senses a movement, the unit will send a Notification Report to the
nodes of Group 1. Once the movement is stopped, a Notification Report will be sent
again to Group 1.
 Upon detector status being changed, the unit will check its battery status simultaneously.
When the battery level of the unit drops to an unacceptable level, the unit will emit
Battery report to the nodes of Group 1.
 When performing Factory Reset the unit will send Device Reset Locally Notification to
the node of Group1.
Group 2 commands:
 When the detector is triggered, the unit will send BASIC_SET command which contains
a value to the nodes of Group 2.
Z-Wave Plus Info
Role Type
Node Type
Slave Sleeping
Z-Wave Plus node
report
Version
Protocol Library
3 (Slave_Enhance_232_Library)
Protocol Version
4.3D ( 6.71.01)
Manufacturer
Manufacturer ID
Product Type
0x0060
0x0001
AGI (Association Group Information) Table
Command Class & Command (List) N
Group
Profile
bytes
Battery Report
1
General
Notification Report
Device Reset Locally Notification
2
Control
Basic Set
Installer Icon
User Icon
Sensor Notification
Sensor Notification
Device Type (Home
Device Type (Home
Security)
Security)
Product ID
0x0005
Group Name(UTF-8)
Lifeline
PIR Control
Notification
Event
The power is applied for the first time
PIR Trigger ON
PIR Trigger OFF
Tamper switch being press more than
10 seconds
Tamper switch being press more than
10 seconds and released
Battery
Battery Report (value)
Description
20~100
Battery Level (%)
0xFF
Low Battery
Command Classes
The module supports Command Classes including...
 COMMAND_CLASS_ZWAVEPLUS_INFO_V2
 COMMAND_CLASS_ASSOCIATION_V2
 COMMAND_CLASS_ASSOCIATION_GRP_INFO
 COMMAND_CLASS_TRANSPORT_SERVICE_V2
 COMMAND_CLASS_VERSION_V2
 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
 COMMAND_CLASS_DEVICE_RESET_LOCALLY
 COMMAND_CLASS_POWERLEVEL
 COMMAND_CLASS_SECURITY
 COMMAND_CLASS_SECURITY_2
 COMMAND_CLASS_SUPERVISION
 COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
 COMMAND_CLASS_BATTERY
 COMMAND_CLASS_WAKE_UP_V2
 COMMAND_CLASS_NOTIFICATION_V4
Wakeup Command Class
After it has been included into a Z-wave network, the detector will go to sleep but will send a
Wakeup Notification Command periodically at preset period to the controller. The Motion
detector will stay awake for 10 seconds at least and then go back to sleep to conserve
battery life.
The time interval between Wakeup Notification Commands can be set in the Wakeup
Command Class based on the range values below:
Minimum Wake Up Interval
Maximum Wake Up Interval
Default Wake Up Interval
Wake Up Interval Step Seconds
Event
Event
Type
Event
Parameters
Parameters
Length
0x08
0x01
0x00
0x07
0x08
0x00
0x07
0x00
0x01
0x08
0x07
0x00
0x01
0x03
0x07
0x03
0x01
600s (10 minutes)
86400s (1 day)
14400s (4 hours)
600s (10 minutes)

Advertisement

loading