EVERSPRING SE812 User Manual

EVERSPRING SE812 User Manual

Z-wave enabled device and is fully compatible with any z-wave enabled network

Advertisement

SE812
INDOOR SIREN
TM
The Indoor Siren is a Z-Wave
enabled device and is fully compatible with any
TM
Z-Wave
enabled network. Z-Wave
logo can also be used with it regardless of the manufacturer, and ours can also
be used in other manufacturer's Z-Wave
Indoor Siren on other manufacturer's Wireless Controller menu allows a full
alarm condition to be generated once a connected Z-Wave
TM
has been triggered. Z-Wave
enabled devices (refer to nodes) in the system
also act as repeaters, so as to re-transmit the RF signal to ensure that the signal
is received by its intended destination by routing the signal around obstacles and
radio dead spots.
The Indoor Siren integrates both functions of siren and strobe into one unit.
Two sound levels, 100dB and 90dB, are available for selection.
receives a RF command, it will either activate its sounder and flash lights or stop
these visual and audible alarm indications.

Product Overview

1
1
2
2
Front View
1
LED Indicator
2
Red Strobe Light
3
Two-Phase Sound Jumper Link
4
Tamper Jumper Link
Include to or Exclude from a Z-Wave
In the rear casing, there is a link key which is used to carry out inclusion,
Confidential Information of Everspring Industry Co.
TM
enabled devices displaying the Z-Wave
TM
enabled networks. Inclusion of this
TM
enabled device
When it
3
3
4
4
Side View
Rear View
5
Tamper Switch
6
Link Key
7
DC Jack
TM
Network
exclusion or reset. When power is first applied, its orange LED flashes on and
off alternately and repeatedly at 2-second intervals. It implies that it has not
been assigned a node ID and cannot work with Z-Wave enabled devices. The
Siren will stay "awake" for 10 minutes when power is first applied to allow time
for configuration. Please get familiar with the terms below before starting the
TM
Function
Inclusion
Add a Z-Wave enabled device (e.g. Siren) to Z-Wave network.
Exclusion
Delete a Z-Wave enabled device (e.g. Siren) from the network.
Association
After inclusion, you have to define the relationship between devices.
Trough association, device can be assigned as master/slave, and
specify which slave is going to be controlled by which master.
Reset
Restore Siren to factory default.
The table below lists an operation summary of basic Z-Wave functions. Please
refer to the instructions for your Z-Wave
access the setup function, and to include/exclude/associate devices.
detector executes the function of auto inclusion when...
Auto Inclusion
The function of auto inclusion will be executed as long as the Siren does not
5
have node ID and in situations where...
5
6
6
1. The power is first applied.
7
7
2. The execution of exclusion/reset is successful where the stored node ID is
cleared.
Note: Auto inclusion timeout is 4 minute during which the node information of
explorer frame will be emitted once every 5 seconds.
function as shown in the table below, the execution of auto inclusion is free from
pressing the link key on the Siren.
Function
Description
No node ID
The Z-Wave Controller does not
allocate a node ID to the Siren.
Inclusion
1. Have Z-Wave Controller
entered inclusion mode.
2. Pressing link key 3 times within
1.5 seconds will enter inclusion
mode.
1
Ltd.
Description
TM
Certificated Primary Controller to
Unlike "inclusion"
LED & Beep Indication
LED: 2-second on, 2-second off;
Beep: 0.1-second on,
9.9-second off
Green LED is on and Siren
beeps when link key is pressed.
The

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SE812 and is the answer not in the manual?

Questions and answers

jaaf
July 4, 2025

I have the 812-1 model since few years. The sound of the alarm became very low - you can barely hear it, even with new batteries. any idea what reaons could be ?

Subscribe to Our Youtube Channel

Summary of Contents for EVERSPRING SE812

  • Page 1 Confidential Information of Everspring Industry Co. Ltd. exclusion or reset. When power is first applied, its orange LED flashes on and SE812 INDOOR SIREN off alternately and repeatedly at 2-second intervals. It implies that it has not been assigned a node ID and cannot work with Z-Wave enabled devices. The Siren will stay “awake”...
  • Page 2 Confidential Information of Everspring Industry Co. Ltd. Function Description LED & Beep Indication Note: You can use power adapter instead of batteries. The power adapter Exclusion 1. Have Z-Wave Controller entered Green LED is on and Siren is an optional accessory. A cable track is set inside the unit for you to exclusion mode.
  • Page 3 Confidential Information of Everspring Industry Co. Ltd. Tamper switch is designed to prevent Siren from being forcibly removed from the ALARM_REPORT Command: wall. Three minutes after it is pressed will enable the function of tamper [Command Class Alarm, Alarm Type = 0x01, Alarm Level = protection.
  • Page 4 Confidential Information of Everspring Industry Co. Ltd. Basic Get Command: [Command Class Basic, Basic Get] Basic Report Command: Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)] Report ON:[Command Class Basic, Basic Report, Value = (255)0xFF] Federal Communication Commission Interference Statement...

Table of Contents