Download Print this page
EVERSPRING SP816 Manual

EVERSPRING SP816 Manual

Outdoor motion detector

Advertisement

Quick Links

SP816
OUTDOOR MOTION DETECTOR
The SP816 Outdoor Motion Detector is a Z-Wave Plus
TM
compatible with any Z-Wave
enabled network. The device can be set up in a Z-wave
network to communicate directly with other end devices such as lighting controllers, or to
report directly to a Z-wave controller (usually a gateway).
This motion detector is primarily designed for outdoor lighting control application. It features
a PIR motion detector to detect movement in a protected area and a lux sensor for
determining brightness of its surroundings. It comes with a built in timer to set the duration
for light turn on. The lux level and the timer can be set through knobs on the device itself.
If the PIR detects motion when lux level falls below a preset setting, the device will transmit
a signal to turn on the outdoor lighting (or indirectly through gateway) and then later turns it
off when its timer has elapsed.
This device can also be used as a basic motion sensor for indoor security application.
Product Overview
 Front Cover
 Motion Sensor
 Time-off / Lux Knob
 LED indicator (hidden behind lens)
TM
Adding to Z-Wave
Network
Auto Inclusion
The detector supports Auto Inclusion feature where it will automatically enter Inclusion
mode when first powered up after a factory reset.
1.
Use a screwdriver to detach the rear cover.
2.
Put a Z-Wave Controller into inclusion mode.
TM
enabled device and is fully
 Battery
 Rear Cover
○ 7 Tamper Switch
3.
Insert 3 AA-size 1.5V batteries to the battery
compartment with the correct polarity. The LED on
the device should turns ON..
4.
The Inclusion process should be completed when the LED stops blinking.
5.
Do not refit the rear cover yet.
Note: If Auto Inclusion fails, refer to the Troubleshooting section regarding Manual
Inclusion.
Testing
Warm-Up
It will take approximately 1 minute for the detector to warm up after a battery is inserted.
During this period the LED behind the lens will turn on. When the LED turns off, it implies
warm-up procedure is complete and the detector is ready for detection.
Note:
- This will not affect the Inclusion/Exclusion process.
- After removing batteries, wait for 5 seconds to refit batteries.
Quick Test
1.
With the tamper switch not being pressed, the unit will enters Test mode to allow the
user to test the device before it is mounted on the wall.
2.
During Test mode, if movement is detected, the LED on the detector will illuminate
implying the unit is working properly.
3.
To exit the Test mode, simply press the Tamper switch for more than 10 seconds to
enter Normal mode.
Mounting the Detector
Choosing the location
The recommended location for the detector is outside the house under the eaves or
other shaded areas where it is not directly exposed to sunlight. Though the detector is
waterproof (IP44 rated), avoid direct contact with rain.
- Do not position the detector facing a window or direct sunlight.
- Do not position the detector directly above or facing any source of heat, eg: fires,
radiators, boiler etc.
- Where possible, mount the detector so
that the path of an intruder would cut
across the fan pattern rather than directly
towards the detector.

Advertisement

loading

Summary of Contents for EVERSPRING SP816

  • Page 1 The LED on SP816 OUTDOOR MOTION DETECTOR the device should turns ON.. The SP816 Outdoor Motion Detector is a Z-Wave Plus enabled device and is fully compatible with any Z-Wave enabled network. The device can be set up in a Z-wave network to communicate directly with other end devices such as lighting controllers, or to report directly to a Z-wave controller (usually a gateway).
  • Page 2 mount the detector 2m from the floor. At this Operation height, the detector will detect movement within its 100 degrees fan-shaped detection When the detector is mounted on the wall, i.e. tamper switch is pressed, for more than 10 pattern up to 6-12m depending on seconds, it will enter Normal mode.
  • Page 3 Notification Programming Event Event Event Type Event Parameters Z-Wave Group Parameters Length The power is applied for the first time 0x08 0x01 0x00 The detector supports either one of two Z-wave Association Groups: PIR Trigger ON 0x07 0x08 0x00 Group 1: Association with 1 Controller node. Group 2: Association with 4 nodes (i.e.
  • Page 4 When replacing old appliances with new ones, the retailer is legally obligated to take back out of order your old appliance for disposal at least for free of charge. 50 Sect. 1 Zhonghua Rd Tucheng www.everspring.com NewTaipeiCity 236 Taiwan A501112630R...