Download Print this page

Electrolux 240379005 Technical Manual page 58

Side by side and top mount refrigerators

Advertisement

PERFORMANCE DATA
NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING
65°F (18°C) Ambient
Type A with Run/Start Capacitor
Variable Speed
Standard
Variable Speed
Operating Time
74 to 84%
32 to 40%
-2° to 2°F
0° to 4°F
Freezer Temperature
-19° to -17°C
-18° to -16°C
-18° to -16°C
34° to 39°F
34° to 39°F
34° to 39°F
Refrigerator Temperature
1° to 4°C
1° to 4°C
5 to 12 psig
5 to 12 psig
Low Side Pressure (cut-in)
43 to 83 kPa
43 to 83 kPa
-2 to 2 psig
-2 to 2 psig
-2 to 2 psig
Low Side Pressure (cut-out)
-14 to 14kPa
-14 to 14kPa
-14 to 14kPa
90 to 105 psig
90 to 115 psig
120 to 135 psig
High Side Pressure (last 1/3 cycle)
621 to 724 kPa
621 to 793 kPa
827 to 931 kPa
Wattage (last 1/3 cycle)
60 to 65
120 to 150
Amps (running)
.7 to 1.1
1.0 to 1.4
Base Voltage
115 vac (127 vac max)
DEFROST SPECIFICATIONS
Thermostat
Cabinet Size
Cut-in
Cut-out
23'
25°F (-4°C)
47°F (8°C)
Electronic Timer – (ADC) Defrost 24 minutes every 6 – 96 hours of compressor run time.
CONDENSER FAN MOTOR
Watts
RPM
2.8
950 CW Opposite Shaft
ICE MAKER SPECIFICATIONS
Electrical
115 vac (127 vac max)
Thermostat
Opens at 48°F (9°C)
Heater Voltage
85 vac
ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number
Wire Color
1
Green/Yellow
2
Yellow
3
Black
4
Light Blue
IMPORTANT
Please return this sheet to its original location.
SERVICE DATA SHEET
ICE & WATER - AUTOMATIC DEFROST
COUNTER DEPTH SIDE BY SIDE - R134a
90°F (32°C) Ambient
IMPORTANT SAFETY NOTE
Standard
100%
55 to 65%
-1° to 3°F
-1° to 3°F
The information provided herein is designed to assist
-18° to -16°C
qualified repair personnel only. Untrained persons should
34° to 39°F
1° to 4°C
1° to 4°C
not attempt to make repairs due to the possibility of electrical
5 to 12 psig
shock. Disconnect power cord before servicing this
N/A
43 to 83 kPa
appliance.
-2 to 2 psig
-14 to 14kPa
IMPORTANT
130 to 155 psig
896 to 1069 kPa
If any green grounding wires are removed during servicing,
65 to 80
130 to 160
they must be returned to their original position and properly
.9 to 1.3
1.1 to 1.5
secured.
115 vac (127 vac max)
Heater
CAUTION
Watts
Ohms
450
30
All electrical parts and wiring must be shielded from torch
flame. DO NOT allow torch to touch insulation; it will char at
Amps
200°F and flash ignite (burn) at 500°F. Excessive heat will
.1 Running
distort the plastic liner.
NOTE
Closes at 15°F (-9°C)
This product comes equipped with an Adaptive Defrost
Connects to:
Control (ADC). To activate manual defrost, press and hold
Ground
the Freezer temperature UP (WARMER) key while pressing
Water Valve
the Fresh Food temperature DOWN (COLDER) key 5 times
Line
within 6 seconds. A "d" in the freezer temperature window
Neutral
and "F" in the refrigerator temperature window will display
when the heater is activated. To deactivate manual defrost,
press and hold Freezer temperature UP (WARMER) key while
pressing the Fresh Food temperature DOWN (COLDER) key
5 times within 6 seconds. "d" and "F" will be displayed until
the defrost cycle is complete. (approx. 8 minutes)
Test Cycling
241639000
Press the momemtary contact on the ON/OFF switch for
approximately 15 seconds. Ice maker will continue to
complete the cycle.
Water Fill Volume
Remove cover by
inserting screwdriver
in notch at bottom
and prying cover from
housing. The water fill
adjustment screw will
change the fill time.
One turn is equal to
20cc (.68 oz.). The
correct fill is 102 to
110cc (3.25 to 3.5 oz.). When a water valve is replaced,
the fill volume must be checked.
ICE MAKER INFORMATION
Water Fill
Adjustment
Motor
Gear
Mounting
Plate
Screws
Mounting
Plate
Screw
Timing
Gear
Ice Maker
ON/OFF
Switch

Advertisement

loading