Page 2
The system is modular and can be expanded to up to 200 buttons and equipped with a keypad. The IP-Fermax doorphone is powered by a 12V power supply that can be used to power the door lock or the IP-Fermax can be PoE powered (Power over Ethernet).
Mounting into the wall ................12 IP-F ............... 13 ONNECTION OF ERMAX IP-Fermax main board ................13 Front panel ..................... 16 Camera (22) .................... 17 Replacement of name cards ..............17 Power supply - clamp (10) ..............18 Micro SD card (4) ................... 18 ................
Page 4
Language settings ................... 31 .................. 31 NETWORK SETTING IP Network setting .................. 31 SIP setting ....................34 WEB server ..................... 38 ..................... 40 ASIC SETTING Phone book ..................... 40 Relays ...................... 43 Door sensors ................... 47 Setting SNMP ..................48 Time profiles ...................
Basic description Features ▪ audio is full duplex with ECHO cancellation ▪ phone book for 999 subscribers with 5 tel. numbers for each (max. 200 physicaly buttons + keyboard) ▪ every subscriber has more phone numbers with progressive or simultaneous calling ▪...
Used terminology • Incoming call - Connection between a Brave and a phone made by selecting an option on the phone. The Brave connects the call after set number of rings. The Brave can be programmed from the phone following a connection by inputting a password.
Page 7
• Internet is worldwide system of mutually connected PC networks • Intranet is PC network similiar to internet but it is „private“. It is designed jsut for small group of subscribers (for example workers in some company) • PoE (Power over Ethernet) is powering via data network cable. •...
The Fermax Skyline expanding push button modules and a numeric keypad are the Fermax VDS / BUS2 modules. The Fermax Skyline expansion modules are connected with the 6-core Fermax cable, which is always a part of each Fermax Skyline expansion module.
Numeric keypad The numeric keypad is the original Fermax Skyline VDS/BUS2 module. It is connected with the 6-core Fermax cable, which is always a part of each Fermax Skyline expansion module. The Fermax keypad is automatically detected in the system, it does not need to be programmed.
Mechanical parts All mechanical parts are the original Fermax Cityline (valid for versions 1AP201IP or 1CP201IP only) or the original modular Fermax Skyline series. IP VarioBell - installation and operating instructions...
1 module. Mount the surface box at the correct height of 1,7m above the floor/ground. Mounting into the wall For flush mounting into the wall use the original Fermax Cityline or Fermax Skyline series of mounting boxes. Prepare the flush mounting box Principe of connecting flush mounting boxes next to each other.
The main board always comes with two push buttons on the board. In the versions 1CP201IP and 1AP201IP both push buttons are used. The modular Fermax Skyline series does not use any of these push buttons on the main board. Only the Fermax Skyline expansion push button modules are used in this case.
Page 14
11. Input for powering of the IP-Fermax 12V AC / DC (consumption approx. 300mA max.). We recommend using direct current (DC) type of power supply. 12. Output 12V DC, max. 300mA, e.g. for powering of a low consumption elektrical lock when there is a PoE type of power for the IP-Fermax doorphone.
Page 15
15. Programming button (after pressing it for 5 sec., the IP-Fermax doorphone will switch to the mapping mode to allocate connected push button modules. When you press the programming button once again, it will save the mapping result to its memory)
Front panel 20. Mounting holes for holding the front panel. After installation close the top hole with a supplied plastic cover with Fermax logo. The bottom hole is covered with a supplied silver colour cover. Both covers and screws are always delivered as accessories with the doorphone.
Camera (22) On the figure below and the previous figure above (22) – detailed description (valid for camera models only): 22a Two-colour LED for status indication. Red=establishing a call, Green=active call, Orange=a switch is switched on (you need to set acoustic signalling of the switch) 22b White LEDs for illumination of the space in front of the camera 22c Sensor of ambient surrounding illumination for controlling of name cards...
Power supply - clamp (10) power supply can be direct (DC) or alternating (AC), it is inpependent on polarity, from 12V the max. consumption is 300mA. The power supply can be used also for powering the elecrical lock, then we recommend to use 12V/1A. You can also use a 24V direct current (DC) power supply.
2. Two sources - the possibility to use independently two power supplies, one for the IP-Fermax doorphone and the other for electric locks. The electric lock 2 is inversely connected (fire escape door). 3. Combination of doors with electric lock and gates in fencing.
Page 20
IP VarioBell - installation and operating instructions...
PoE power supply source The IP-Fermax doorphone is equipped with a circuit for PoE powering over UTP cable. If you have a PoE power switch, or you own a PoE (a box of the size of the AC adapter plugged into the UTP cable - according to the IEEE802.3af standard), you no longer need a 12V power for the doorphone´s function.
IP-Fermax doorphone and the code relay board (COSW) is identical. In the IP-Fermax doorphone you can set the Security code for the output to activate the COSW code relay. The code information is 8 bits, but the code entry is 4 bits with 4-bit security, which is a total of 8 bits.
– you need to create a relation to the party number in the phone book). This is done similarly to the VDS Fermax system. On the basic side of the IP-Fermax doorphone (above the MicroSD card slot) there is a button (15).
Signalling overview Overview of signalling The IP-Fermax doorphone is signaling acoustic states that can occur during operation, additional signaling is via two-color LED (located above the camera). The acoustic signaling for each state listed in the table below can be turned off or the default beep tone is used or replaced by user sounds.
Dial again Call is ended Since version 3.0.38 is in guard IP Fermax new property that upon arrival "SIP Ringing" or the "Session progress" will not pass audio, but lets local bell ringing. But the video link (if offered by the counterparty in the SDP). Thus, it is possible with a suitable videophone (eg.
Incoming call is call to door entry (start by person inside building). After dial of extension number or IP adress where is connected door entry IP Fermax the door entry is ringing and after preprogrammed number of rings picks up the call.
Stream video for IP phones: H.263 and H264 is established by IP Fermax door entry and IPvideo phone over SIP/SDP protocol on standard SIP port. The video (as same as sound) then runs by RTP protokol on ports agreed over SIP (usually 9078).
If you get into a situation that you do not know the IP address set in IP Fermax or have forgotten your password, so there is reason to use the DIP2 switch, switch it to the ON position and restart IP Fermax. Then you change the settings eg.
IP address you have return setting in PC back. Then you can setup parameters of door entry including IP address and after restart of IP Fermax door entry you can login to door entry WEB page on new IP adress.
Current status Current status display basic data about IP Fermax door entry status. It displays Firmware version,door entry model, options connection (camera), SD card, MAC adresses, current time, network setting, door entry mode (P2P or SIP server), registration status and small calls statistic.
Language settings After language selection please don’t forget click on „Save changes“. On the right top corner is display flag of current used language in whole WEB interface. After click on flag accessible language will be displayed. After language selection please don’t forget click on „Save changes“ otherwise language selection wont be performed.
Page 32
After performing of required changes please don’t forget click on „Save and restart“. Setup via DHCP - ON / OFF using DHCP assignment of IP adresses IP adress, Network mask – IP adress setting, mask. In case of emergency please contact your network administrator Network gateway –...
Page 33
DHCP – by mark of this checkbox as same as saving and restart will be assigned to door entry IP Fermax - IP adress by DHCP. NAT policy - there is the choice of what kind of translate IP addresses used...
SIP setting The door entry IP Fermax might operates in 2 basic SIP modes. It is either SIP server – door entry registration is performed to SIP server and then you call to phone numbers assigned by SIP server or Peer to Peer (P2P) –...
Page 35
Account - unit name in SIP protocol (usually line number or name without diacritics) Auth.ID - name for SIP server registration Password - password for SIP server registration Send register – when registration is necessary (mostly yes) then this parametr must be used Registration server - IP adress or server name of registration server (in most systems and installations is enough to insert IP adress).
Page 36
Peer to Peer mode (P2P) After performing of changes please don’t forget click on „Save changes“. Display name – name by which is device presented in network (for example will display as door entry name in programms iBell, UDVguard) SIP User Agent – for easy inastallation is possible use the SIP user agent.
Page 37
P2P mode, as well as applications for iOS - Apple. The principle of setting SIP phones and UDV guard, iBell with IP Fermax: 1. Mode of phone is SIP server registration is IP address IP Fermax (registration or SIP server = IP address IP Fermax) 2.
WEB server After performing of changes please don’t forget click on „Save and restart“. WEB interface TCP port - posibility of chase usuall TCP port 80 to other (security reasons) Service password / Retype password – inserting of new access password (instead default password 1234) –...
Page 39
ON / OFF access from telnet (name: root, pass: 8765). telnet is not recommended, in practice, this possibility has caused a lot of problems. Damage Doorphone IP Fermax unprofessional intervention via Telnet warranty will be void Doorphone IP Fermax.
After performing of changes please don’t forget click on „Save“. The phone book contents 999 subscribers. For first 200 subscribers agree subscriber number with button number. In this version of door entry – IP Fermax is max = 200 button. Therefore first 2 subscribers are most important.
Page 41
Every position of phone book allows insert up to 5 phone numbers with possibility to join some of them (or all) into group and call group of phone numbers simultaneously. Title – This text has informative character only. In case of display using will be name shown in list selection.
Page 42
according buttons 1 – 2 in this model). Each subscriber has one cod efor every relay. Calling – description The group means that 2 or more phone numbers creates group and those Numbers are dialled simultaneously (all are ringing together). Who from dialled Subscribers pick up first can talk and ringing to other subscribers in group Will be ended.
In relays setting are accessible 4 relays. The relays 1 and 2 is output of relays contacts directly in IP Fermax door entry. Next 2 relays (3 and 4) is possible use for remote relays (IP relays via follow) or as virtual relay usefull for synchronization to allows creation of more difficult functions of relays.
Page 44
function. When such status repeats regularly (for example school) you can use time plan. Time table – defines time period when relay is working and hen not. For example is shop operation time , school, etc.. Relay mode - monostable – by code is closed and after preprogrammed timeout is open.
Page 45
Caution – do not fill code when electrical lock without COSW is connected. It can demage relay in door entry IP Fermax! Direct ON button – when you fill up button number then this number will work as departure button only.
Page 46
Closing switch 1 from buttons – on the picture is filled with code 11221 with time limitation (open time), closing the switch is activated by pressing a sequence of buttons 11221 on IP Fermax IP VarioBell - installation and operating instructions...
Door sensors Door sensors are special functions of door entry IP Fermax which is optional. It is HW option which is different according button number of each model – inputs for door sensors. There is created information in the system about close/open the door.
Input door sensor 1 / 2 Exit button – relay 1-4 – because the use of door sensors not found so wide usage, so these can be used as two inputs to the function Exit button. When the input connections (short) so activates the corresponding relay (switch monostabil) .
Variables in MIB tree – is designed for identification of none sense numeral chain OID OID is numeral identificator which definitely identify every value in SNMP communication. OID is created by number sequence separand by dot. Every dot represent exact level of tree structure into which are OID maped.
possible deactivate whole day (first item on the row select „Active“ – Yes /No) . In example on the picture it is Saturday or whole day setup on active – in example i tis sunday. To use correctly this feature is necessary to setup correct time in the unit (via Date and time setting) Code for activation / deactivation–...
Page 51
Network time server – IP adress or domain name of NTP server. When you dont know then by inserted * will IP Fermax find NTP server automatically according own selection. Condition is setup in network setting start gate and DNS.
When you want inform subscriber about missed calls from door entry you can setup IP Fermax to sent out email after every missed call. You can setup own subject and text of email. When you have door entry with camera you can automatically add to email one or more pictures from camera.
Page 53
SMTP port – adjust in case of none standard SMTP server setting only. SMTP port is setup usually on value 25, but better is use port 587. SMTP, there are three systems: Port 25 not allow encrypted - it is marked as obsolete, insufficient safety Port 465, not a domain hosting - is labeled as not recommended at Port 587, has no maladies previous two, is currently the only recommended variant...
Extended setting This part is designed for system setting which are done once during installation or when are problems with device kompatibility. DoorPhone After performing of changes please don’t forget click on „Save“. Ringing timeout – time for which is ringing. When is setup more numbers as same as progressive ringing then after this time ringing is ended on first phone number (IP adress in P2P) and starts ringing on second.
Page 55
- call is repeated - nothing happen Active button by HTTP – if checked, so is possible use http request for remote activation button (like as press the button. This feature is for easy check the installation IP Fermax. Example: http:// IPaddress...
Page 56
ATTENTION The lower limit must always be less than the upper limit, as the difference between the two values is the hysteresis (recommended to maintain approximately 50) IP Fermax Počet rozšiřujících tlačítek – zde se zadává počet tlačítek rozšiřujících modulů. Toto číslo je součet tlačítek připojených na základní modul. Základní modul má...
Audio setting After performing of changes please don’t forget click on „Save“. Speaker volume + Microphone gain – amplification setting ECHO limiter – it is designed for Echo cancellation which is created by distortion of loud signal.During standard door entry call is working automatic adaptive echo canceller which cancel the echo after cca 3 seconds of talk and call is full duplex.
- default, simple signalling in default setting - user, this is recorded signalling by user ( SD card) -via. Service Volume – loudness signalling adjustment Audio codecs After performing of changes please don’t forget click on „Save“. Priority – setting of codecs priority for usage. Some audio codecs requires payable license (for example G729) –...
Video setting After performing of changes please don’t forget click on „Save“. Image size– image size selection. Stream H.263 knows just CIF resolution (352x288) so bigger image is cut and smaller image is framed Images per second – this setting concern mainly image transmission to WEB browser.
PC adress with installed and running programm then you can receive call through sound card in PC. By click to DoorPhone button in programm you can call to door entry IP Fermax – CAUTION PC sound card ECHO canceller setting !! - Programm might be installed to max.100 computers in network.
Video codecs After changes performing please don’t forget click on „Save“. Priority – setting of codecs priority for usage . Compatibility – Due some of VOIP phones producers specialities you have to use in certain cases extra setting: Yealink – phonesYealink SNOM –...
After changes performing please don’t forget click on „Save“. Enable streaming – permitted / prohibited to provide video (H.263 and H264) by door entry IP Fermax (server) protocol RTSP on port 554. To receive such video you need some standard stream video players (IP TV or for example Grandstream, MPlayer, VLC etc…).
Page 63
Multicast adress – by inserting IP adress you permit sending RTP packets to selected multicasting adress. JPEG image quality – you insert percentage of video coding quality IP VarioBell - installation and operating instructions...
Service This part contents service functions. Restart By click on „Restart“ button you make door entry reset. IP VarioBell - installation and operating instructions...
Configuration The door entry IP Fermax allows saving of current setting to PC or other repositury. From this saved file you can later restore this setting in a few levels – for example phone book only. It helps for example during installation of door entry in more entries to the building.
File with customization use from firmware V3.4.2 on this place for change the style (design) of WEB pages in doorphone IP Fermax /*.custom/. Load logo file – by click to empty field select the file and by click to „Make” is logo file.
Clean languages – it allows erase all added languages except factory languages En+Cs (mark and click on perform) Load language file – by click to empty button select the file and by click to „Make” is new language file loaded. Save language file –...
Page 68
To create new language we recommend following steps. Firstly make export of language file (language version of exported file is simultaneously selected language ( flag in right top corner). Rename this file to new language and open in text editor (PSPad is recommended because file has rows ended by LF only and no CR+LF as usual).
Firmware upgrade Firmware version – display present firmware version in door entry IP Fermax Choose firmware file – by click to empty field select file with firmware (for example apt.firmware it is not file *.zip, but already unzip file – on website are firmware files packed to archive *.zip)
After firmware upgrade you must make restart of doorphone IP Fermax. Logfile Start enhanced log – it is OFF in default to save processor efficiency. When you switch it ON then are save into internal memory detail information about door entry operation. It is very helpfull to solve different problems ( compatibility etc..).
Page 71
Syslog server – IP adress or server name of syslog server where will be sent records about IP Fermax door entry operation (do not forget setup NTP server for setting of internal door entry clocks otherwise records will be saved with incorrect date and time) The procedure to download Enhanced LOG file.
License This page allows extend door entry features about payable functions via licenses.For example audio codec G729. After payment you receive license number by email License validity shows if license is working correctly. The license code is connected to MAC number of door entry. IP VarioBell - installation and operating instructions...
Sound files This page is designed for recording own (user) sounds signalling. By click on „Play“ will be played currently active sound file (selection is permormed on page „Audio setting“ eventually sound of relay closing on page „Relays“). Attention files are recorded on a microSD card! Audio files: WAV –...
Max. consumption 300mA 12Vss Max. switching voltage when I < 1A relays Max. switching current by relays when U < 30 V - 20 to + 80°C Temperature range Mechanical dimensions Fermax - IP VarioBell - installation and operating instructions...
Stream video for IP phones: H.263 and H264 is established by IP Fermax door entry and IPvideo phone over SIP/SDP protocol on standard SIP port. The video (as same as sound) then runs by RTP protokol on ports agreed over SIP (usually 9078).
Page 78
Guarantee conditions: The product was shop-checked. The producer guarantees that this product will keep the features described in these operating instructions in the course of guarantee provided that the user will be handled with it as described in the operating manual. Particularly the warranty does not cover damage from improper intervention via Telnet.
Need help?
Do you have a question about the IP-Fermax IPF-00 and is the answer not in the manual?
Questions and answers