Demo Kit
2nd Tier
(Default = off) This setting determines whether the panel is
used for a standard installation (off) or as a demo kit (on). The
demo kit will include:
Allegro panel
SAW D/W
2 button key fob
PIR plastic (motion sensor)
DTIM plastic
9V alkaline battery with battery strap
Soft-sided case
Demo kit Instructions
The following contains the modifications to Allegro Software
that embody the Demo Kit Software. All features work exactly
as on the production version except those listed here.
Power Up Default Deviations
The power-up defaults are the same as the production version
except the following:
Zones
Zone Number
1
KEYCHAIN
REMOTE
2
FRONT DOOR
Miscellaneous
Item
Default
Demo kit
ON
CPU low battery
OFF
Quick arming
ON
Panel panics
ON
Entry delays
8 seconds
Exit delays
8 seconds
Siren time-out
1 minute
Trouble beeps
OFF
Panel tamper
OFF
All program items can be changed by the operator but will
return to defaults upon a memory clear execution.
Behavioral Differences
A transformer is not required for the Demo Kit. AC power
tests will never be performed and AC power failure will never
be shown.
The prompt for setting time after a power cycle will never be
shown.
14
Preliminary 2/5/02
(Options)
Text
Reports (1st Tier)
AC Fail
2nd Tier
(Default = off) When AC Failure is on, the panel reports to the
central station 15 minutes after AC power to the panel is lost.
Note
For UL Listed installations, AC Failure must be set to on.
To turn AC failure reports on or off:
Press # to turn on or off.
Low CPU Battery
2nd Tier
(Default = on) When this setting is on, the panel reports a low
panel battery to the central station before shutting down.
Note
Panel will not call in a low CPU battery within the first 24
hours of being powered up.
Note
For UL Listed installations, the Low CPU Battery feature
must be set to on.
To turn low CPU battery reports on or off:
Press # to turn on or off.
Phone Test
2nd Tier
(Default = on) This setting determines if the user can, at any
time when disarmed, test the communication between the
panel and the central station. If a DTIM is installed with the
system:
The panel sends a packet to the DTIM informing it to send
a phone test report to the central station. The report will
be sent out immediately.
The DTIM will send a successful or failed phone test mes-
sage to the panel.
The panel will display
PHONE TEST FAILURE
test is unsuccessful.
The panel will display
TEST PASS
cessful.
If a central station phone number is not programmed the
panel will not display the option to do a phone test.
If a DTIM is not enrolled the panel will not display the
option to do a phone test.
High or Low level reporting must be on.
To turn the phone test setting on or off:
Press # to turn on or off.