Timers (1st Tier)
Entry Dly
2nd Tier
(Default = 30 seconds, Parameters = 30-240 seconds) Entry
Delay determines how much time the user has to disarm the
system after entering the armed premises through a
"designated delay door," (grp 10) without causing an alarm.
Note
For UL Listed installations, the Entry Delay must be set to
45 seconds or less.
To set the entry delay:
Press #, enter desired time and then press #.
Exit Dly
2nd Tier
(Default = 60 seconds, Parameters = 45-254 seconds) Exit
Delay determines how much time the user has after arming the
system to leave the premises through a "designated delay
door," (group 10 or 19) without causing an alarm.
Note
For UL Listed installations, the Exit Dly must be set to 60
seconds or less.
To set the exit delay:
Press #, enter desired time and then press #.
Phone Test Frequency
2nd Tier
(Default = 7 days, Parameters = 1-255 days) Phone Test
Frequency determines how often the panel conducts the
automatic phone test. The system can be set to perform an
automatic phone test anywhere from every day to every 255
days. To turn this option off, turn off Auto Phone Test under
the Reports option.
Note
For UL Listed installations, the Next Phone Test and Phone
Test Frequency must be set to 1.
To set the phone test frequency:
Press #, enter desired number of days and then press #.
Next Phone Test
2nd Tier
(Default = 7 days, Parameters = 1-255 days) Next Phone Test
is used by the Auto Phone Test feature to determine when the
next automatic phone test should occur. This setting should be
the same as, or less than, the Phone Test Frequency setting. To
turn this option off, turn off Auto Phone Test under the Reports
option.
To set the next phone test:
Press #, enter desired time (1-255 days) and press #.
Allegro
Preliminary 2/5/02
Sleepy Time
(Timers)
2nd Tier
(Default = on) Sleepy Time determines whether sleep hour is
enabled or disabled. If enabled, proceed to Sleep Hour to set
the sleep time desired.
Important !
Fire related trouble beeps are not affected by Sleepy Time.
Note
For UL Listed installations the Sleepy Time option must be
set to off.
To set the sleepy time:
Press # to turn on or off.
(Timers)
Sleep Hour
2nd Tier
(Default = 22, Parameters = 0-23) Sleep Hour determines the
start time of a 10 hour window during which trouble beeps are
suppressed. For example, if sleep time is set to 22 (10 p.m.)
then non-fire related trouble beeps will not start between 10
p.m. and 8 a.m.
To set the sleep hour:
Enter desired time (00-23) and then press #.
Options (1st Tier)
KTP Arm
(Timers)
2nd Tier
(Default = off) When Keychain Touchpad Arm is on, pressing
the lock button on keychain touchpads arms the system
directly with NO DELAY.
When this setting is off, each key-press increments the arming
level without NO DELAY.
To turn keychain touchpad arm on or off:
Press # to turn on or off.
Police Panic
2nd Tier
(Default = on) This setting determines whether panel keypad
police panic buttons are enabled (on) or disabled (off). If
(Timers)
enabled, an immediate Police alarm will occur after the police
panic buttons are pressed for two seconds and the panel
displays the alarm as a police panic. If the DTIM is installed
with the system;
An alarm report will be issued.
If the dialer delay option is on, the report will be delayed
or can be aborted.
To turn the police panic on or off:
Press # to turn on or off.
(Timers)
(Timers)
(Options)
(Options)
11
Need help?
Do you have a question about the Allegro and is the answer not in the manual?
Questions and answers