5.2.8

Minimum Trigger Pulse Length

A digital signal debouncer helps to ensure that the camera does not respond to spurious electrical signals that are
shorter than 16 ticks of the current
the camera responds to a trigger signal.
Revised 10/31/2013
Copyright ©2011-2013 Point Grey Research Inc.
Sensor Input Clock
setting. This safeguard results in a minimum 16-tick delay before