Mounting - Siemens SITRANS AS100 Operating Instructions Manual

Acoustic sensors
Hide thumbs Also See for SITRANS AS100:
Table of Contents

Advertisement

Mounting

Note
• To ensure the most ideal location, test the SITRANS AS100 by clamping the Sensor to
the application, and running a trial period to determine the system's performance. The
acoustic emission level can be monitored by a voltmeter across the analog output. Refer
to Interconnection (Page 21).
• Coating the contact surfaces with grease enhances the propagation of acoustic emissions
to the Sensor.
Direct Mounting
Clearance Hole
Insert mounting post
through hole in device being
monitored and fasten with
customersupplied washers
and nut.
Note
To ensure proper coupling, the face of the Sensor nut must be tight to the application
surface.
SITRANS AS100
Operating Instructions, 06/2016, A5E31952194-AB
Mounting Method
Clearance hole
Drill and Tap
Mounting Disc
Extension Tab
Drill and Tap
Screw mounting post into
threaded hole in device
being monitored.
Acoustic Coupling and Sensitivity
Good
Good
Good
Fair
Contact
Weld or bond mounting post
to device being monitored.
When welding, first remove
the acoustic sensor from the
housing.
5
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents