Summary of Contents for Siemens Ay

  • Page 1 User Manual for AyAlarm AyTerminal V2.1 User Manual for AyAlarm V2.1 AyTerminal © Siemens AG Österreich 2007 Issued by Siemens AG Österreich (Siemens Austria) Program and System Engineering PSE CSS MPS Gudrunstraße 11 A-1100 Vienna Page 1 of 52...
  • Page 2: Table Of Contents

    4.2.3 PIN/PUK input ....................... 13 4.2.4 Boot screen ........................14 5 AyAlarm application ........................16 5.1 AyAlarm menu structure ....................17 Issued by Siemens AG Österreich (Siemens Austria) Program and System Engineering PSE CSS MPS Gudrunstraße 11 A-1100 Vienna Page 2 of 52...
  • Page 3 5.8.7 Security ......................... 50 5.9 Turning off the AyTerminal ....................51 5.10 Involved sensors in AyAlarm modes ................52 5.11 Symbols on AyTerminal ....................52 Issued by Siemens AG Österreich (Siemens Austria) Program and System Engineering PSE CSS MPS Gudrunstraße 11 A-1100 Vienna...
  • Page 4: Introduction

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application 1Introduction 1.1Purpose of the document The purpose of this document is to describe and specify in detail the GUI for the product AyAlarm, an AyTerminal application. It is based on the version 1.0 of the AyAlarm application. 1.2Validity of the document This document is valid for the AyTerminal project, a subproject of AySystem.
  • Page 5: Quick Instruction / Reference

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application 2Quick instruction / reference 2.1Device description The detailed device description you find in chapter 3.1. The major parts are: • Display (OLED display): Used for information screens and for input screens. There are 2 display modes: standard mode and jumbo mode (big-sized characters) See chapter 3.1.9.
  • Page 6: Activating A Mode

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application • Baggage Secure: Activation Time (see chapter 5.4.1) Autostart (see chapter 5.4.2) Notifiers (see chapter 5.4.3) Triggers (see chapter 5.4.4) Duration (see chapter 5.4.5) • Room Monitor: Activation Time (see chapter 5.4.1) Autostart (see chapter 5.4.2) Notifiers (see chapter 5.4.3) Triggers (see chapter 5.4.4)
  • Page 7: Ayterminal Device

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application 3 AyTerminal device 3.1Device description AyTerminal is a device that enables phone calls, temperature, noise and acceleration measuring, sounding alarms or notifying user via web pages, voice call and/or SMS. All this numbered features are AyApplication specific.
  • Page 8: Hold-Switch

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application Hold-switch Figure 3-4 Hold-switch 3.1.1Hold-switch This switch prevents unintended button presses, see Figure 3-4. A button press is accepted only in case the switch is in position “unlock”. If the hold-switch is in position “lock“ the only accepted action is the long-press onto the central button, if this is enabled by AyApplication e.g.
  • Page 9: Lumberg Connector

    3.1.3Lumberg Connector Using this 12 pin slim Lumberg connector is possible to: • Connect a Siemens standard headset and to use it for GSM voice calls. • Connect the AyTerminal charger for charging the AyTerminal battery. This slim Lumberg connector used for the developer AyTerminal version makes possible the upload and debug of the developed AyApplications via data cable (see Figure 3-2).
  • Page 10: Speaker

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application Up button Left touch button (Back) Entry touch button (OK) Figure 3-5 Current AyTerminal design. Down touch button Display and central button 3.1.5.1Navigation through the menu structure In a menu layout the first menu item is selected by default. Another item can be selected by pressing up/ down button.
  • Page 11: Microphone

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application 3.1.6.2Ring tones There are 7 available ring tones which can be used in AyApplications. With AyCare application these ring tones can just be played from Settings/ Audio/ Ring tones. 3.1.6.3Alarm tone Alarm tone is an internal alarm which is used in AyCare for playing siren in case of alarm (if the mode is defined so).
  • Page 12: Installation And Startup

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application Charging Charging finished finished Charging Charging Interrupted interrupted Figure 3-6 Charging possible states of AyTerminal 3.1.11.2Connecting a charger & AyTerminal switched on If the device is switched on and a charger is connected, the charging battery symbol will be shown while the status bar is shown.
  • Page 13: Startup

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application 4.2Startup Press the central button of the device for 2 seconds in order to turn on AyTerminal. A correct startup is indicated by the LED blinking green and a simple animation is shown on the display Figure 4-8.
  • Page 14: Boot Screen

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application from 0 to 9). The PIN is requested to have between 4 and 8 digits. Because of this constraint the OK option is shown and can be selected after the 4th digit was inserted. Enter PIN Enter PIN ***_...
  • Page 15 V2.1 AyAlarm application Welcome Welcome <Nickname> <Nickname> to Ay to Ay <AyAppl.> <AyApplication> Figure 4-16 AyTerminal boot screen – standard and jumbo mode If the AyTerminal is not registered to the AyServer then the default nickname is displayed. Default nickname is “John Doe”.
  • Page 16: Ayalarm Application

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application 5AyAlarm application The AyAlarm AyApplication has six modes (see chapter 5.2 for more details). It can be defined how to be notified if an alarm is triggered: • By sending an SMS to a defined phone number •...
  • Page 17: Ayalarm Menu Structure

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application 5.1AyAlarm menu structure Start Active Active Alarm Clock Activation Time Start <Phone number> Autostart Baggage Secure Active Notifiers Siren <Phone number> <alarm time> Room Monitor Duration Voice Call Overview Car Alarm AyServer Start Active Active...
  • Page 18: Modes Description

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application 5.2Modes description All modes provide a similar menu structure. 5.2.1Alarm clock This mode provides an alarm clock. A timer can be set on a daily basis. An alarm is triggered when the defined time is reached. For configurable values and notifiers refer to chapter 5.4.3.
  • Page 19: Ayalarm Mode Specific Settings

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application 5.2.7AyAlarm mode specific settings configurable format & default description value restrictions value Auto start flag if mode is Boolean false enabled to false – disabled automatically true – enabled start-up Activation time flag if mode is Boolean false...
  • Page 20 User Manual for AyAlarm AyTerminal V2.1 AyAlarm application configurable format & default mode description value restrictions value Alarm Clock Duration * duration of alarm/alarm Time format is 1 minute state ( in case of alarm hh:mm:ss. triggered) Max. 30 minutes * time period for activating Min.
  • Page 21 User Manual for AyAlarm AyTerminal V2.1 AyAlarm application configurable format & default mode description value restrictions value Baggage Duration * duration of alarm/alarm Time format is Secure state ( in case of alarm hh:mm:ss. triggered) Max. 30 minutes * time period for activating Min.
  • Page 22 User Manual for AyAlarm AyTerminal V2.1 AyAlarm application configurable format & default mode description value restrictions value Room Duration * duration of alarm/alarm Time format is Monitor state ( in case of alarm hh:mm:ss. minutes triggered) Max. 30 minutes (300s) * time period for activating Min.
  • Page 23 User Manual for AyAlarm AyTerminal V2.1 AyAlarm application configurable format & default mode description value restrictions value Car Alarm Duration * duration of alarm/alarm Time format is state ( in case of alarm hh:mm:ss. minutes triggered) Max. 30 minutes * time period for activating Min.
  • Page 24 User Manual for AyAlarm AyTerminal V2.1 AyAlarm application configurable format & default mode description value restrictions value Temperature Duration * duration of alarm/alarm Time format is Watchdog state ( in case of alarm hh:mm:ss. minutes triggered) Max. 30 minutes * time period for activating Min.
  • Page 25 User Manual for AyAlarm AyTerminal V2.1 AyAlarm application configurable format & default mode description value restrictions value Voice Call SMS notifier flag if SMS notifier Boolean false active enabled false – disabled true – enabled SMS phone target phone number for Max.
  • Page 26: Ayalarm Alarms And Notifiers

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application 5.2.8AyAlarm alarms and notifiers available mode alarm name description default notifiers notifiers Alarm Clock Time triggered if Siren, SMS, Siren, defined time Voice Call, AyServer reached AyServer Baggage Baggage triggered if Siren, SMS, Siren, Secure ego-motion...
  • Page 27 User Manual for AyAlarm AyTerminal V2.1 AyAlarm application • Baggage Secure • Room Monitor • Car Alarm • Temperature Watchdog • Voice Call • Emergency Call • Settings • Turn Off By default the first menu item is selected. Everywhere in the AyApplication the menu is circular which means that after the last item comes the first item and in front of the first item is the last item.
  • Page 28: Configuring A Mode

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application • Notifiers – to configure the alarm notifiers of this mode. For details see the chapter 5.4.3. • Triggers – to configure the alarm triggers of this mode. For details see the chapter 5.4.4. •...
  • Page 29 User Manual for AyAlarm AyTerminal V2.1 AyAlarm application End time End time 13:00:00 13:00: Figure 5-23 Activation time – Set end time screen The activation time is applied to the mode as long as the “Active” check box is checked. To disable the activation time uncheck the “Active”...
  • Page 30 User Manual for AyAlarm AyTerminal V2.1 AyAlarm application Examples: 1. Start and end time for “Room Monitor” mode: 11:00 and 15:00. The “Active” item in the menu is checked, which activates the defined activation time. The “Car Alarm” mode was configured with inactive activation time, which makes the mode immediately active when starting it.
  • Page 31: Auto Start

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application on the display is updated. The mode becomes again idle when the end time is reached (15:00 o’clock). If no change is made, the same scenario will be repeated the next day. In Figure 5-26 Activation time example 3 the mode is deactivated at 17:00.
  • Page 32 User Manual for AyAlarm AyTerminal V2.1 AyAlarm application 5.4.3.2SMS The SMS data are: the phone number and the message text. The message text can not be defined/ modified on AyTerminal. For each mode there is a default value for SMS text defined (see Table 5-5 AyAlarm mode specific settings) and it can be changed only using the web GUI.
  • Page 33 User Manual for AyAlarm AyTerminal V2.1 AyAlarm application will be displayed in the menu. If the phone number is not defined then in the menu will appear “<Enter Nr.>”. Pressing the left button of the device leads to the previous screen. In “Voice Call”...
  • Page 34: Triggers

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application Notifiers Notifiers Siren Siren Voice Call Voice Call £ AyServer Figure 5-32 AyServer not available case 5.4.4Triggers Each mode has its own list of alarm triggers and each one of them is configurable independently. At least one trigger has to be activated.
  • Page 35 User Manual for AyAlarm AyTerminal V2.1 AyAlarm application Triggers Triggers Temperature Temperat Activation delay Activation Figure 5-36 Setup triggers menu for Temperature watchdog mode In case of the Voice Call mode the user has the possibility to define a phone number where to call instead of the “Triggers”...
  • Page 36 User Manual for AyAlarm AyTerminal V2.1 AyAlarm application <sensor> <sensor> curr.:+24°C curr.: ≥ °C Figure 5-38 Sensor setup screens 5.4.4.1Listen-In The following menu is provided for setting the Listen-In parameter values: Listen-in Listen-in Active Active +40777777333 +40777... Figure 5-39 Setup Listen-In trigger The phone number is the currently set phone number (e.g.
  • Page 37 User Manual for AyAlarm AyTerminal V2.1 AyAlarm application Timer Timer 12:00: 12:00: Figure 5-41 Set alarm clock screen The colons are displayed after the second and fifth digits are inserted. OK option is displayed only after inserting the time in complete format (hh:mm:ss). To leave this screen and set the value the user must first select OK option and then press the enter button.
  • Page 38 User Manual for AyAlarm AyTerminal V2.1 AyAlarm application Noise Noise Active Active Threshold Threshold Figure 5-44 Setup ego-motion menu screen The available buttons and screen’s functionality are the same as in every menu screen. Using a sensor adjustment screen the noise threshold can be set (see Figure 5-45 Noise adjustment screen).
  • Page 39: Duration

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application Temperatur Temperature curr.:+24°C Current: +24 °C > °C > °C Figure 5-47 Temperature adjustment screen The first threshold value of the sensor is the default value (the default value can not be modified using the AyApplication).
  • Page 40 User Manual for AyAlarm AyTerminal V2.1 AyAlarm application Alarm clock Duration: Current 19:54 01:00 Timer 20:54 Notifiers: Alarm clo 19:54 Timer Current 20:54 19:54 Notifiers: Figure 5-49 Overview screen for Alarm Clock mode The overview screen contains the following data: •...
  • Page 41: Activating/Starting A Mode

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application 5.5Activating/Starting a mode A configured mode can be started by choosing “Start” in the mode menu. If the Activation time is checked the mode is first going in idle status and is activated at the specified time. Else the mode is activated immediately when “Start”...
  • Page 42 User Manual for AyAlarm AyTerminal V2.1 AyAlarm application Be aware Be aware that no notifier is that no activated. notifier is Figure 5-52 No notifier activated message box After starting a mode or starting the AyTerminal with the PIN of the SIM card disabled and the mode set to auto start, a screen like in Figure 5-53 is shown in following cases: •...
  • Page 43: Deactivating A Mode Or A Triggered Alarm

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application <mode nam <mode name> <sensor>=<v <s>=<valu Car Alarm Car Alarm Noise=28% Noise=28% Alarm Clock Voice Call Alarm! Alarm! Figure 5-55 Mode active and alarm triggered 09:05 09:13 09:23 Mode Triggers Alarm stopped Alarm triggered activated Mode activated...
  • Page 44: Settings

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application <Mode n> Emergenc Emergency call Settings Settings Turn OFF Turn OFF Figure 5-57 Main menu – standard and jumbo mode 5.8Settings The “Settings” menu provides the possibility to configure general AyTerminal settings via its submenus and menu items.
  • Page 45: Aysnapon

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application 5.8.2AySnapOn The “AySnapOn” menu provides the ability to: • search for new AySnapOns that are connected to the AyTerminal • view all found AySnapOns In the list of found AySnapOns it is possible to: •...
  • Page 46 User Manual for AyAlarm AyTerminal V2.1 AyAlarm application AyTerminal AyTerminal AyApplicati Default set <AyApp 1 <AyApp 4 <AyApp 2 FW Update Info <AyApp 3 <AyApp 1 Default sett Figure 5-65 AyApplication menu – jumbo mode AyApplication AyApplication changed. changed. REBOOTING! REBOOTING! Figure 5-66 Rebooting message box in standard and jumbo mode 5.8.3.1Setting the AyApplication to default settings...
  • Page 47 User Manual for AyAlarm AyTerminal V2.1 AyAlarm application Selected language Display – jumbo mode deactivated Table 5-7 AyTerminal settings – default values For AyAlarm mode related settings see Table 5-5 AyAlarm mode specific settings and Table 5- 4 AyAlarm – settings available for all modes. 5.8.3.2 Firmware Update In the “Firmware”...
  • Page 48: Audio

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application • • • NET username • NET password • AyServer URL This information can not be changed via AyTerminal. MSISDN: Bootloader: 1r15 MainFW: 1r28 +12345678 MSISDN: +1234567890 APN: APN: Figure 5-71 Info message – standard and jumbo mode If the information is not fitting in one screen (one screen has 20 lines in standard and also jumbo mode) then the text is split in more message boxes.
  • Page 49: Clock

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application 5.8.5Clock This menu gives the possibility to: • see current time and date • set the time and date manually • activate/deactivate automatic time synchronization with the AyServer On the AyTerminal the user has to set the time manually or if registered to the AyServer the time can be automatically synchronized on connection to AyServer.
  • Page 50: Security

    User Manual for AyAlarm AyTerminal V2.1 AyAlarm application Using Jumbo mode menu item the user has the possibility to activate or deactivate the jumbo mode of the display 5.8.7Security The Security menu contains following items: • Deactivation code • PIN control (preceded by a checkbox) •...
  • Page 51: Turning Off The Ayterminal

    After the main menu is displayed , select “Turn Off” item in order to turn off the Ay. Message box will appear asking for turning off confirmation, see Figure 5-84. After pressing accept button new message is shown informing about Ay settings being saved, see Figure 5-85.
  • Page 52: Involved Sensors In Ayalarm Modes

    Figure 5-85 Saving AyTerminal settings After saving the settings, Ay is sending SHUTDOWN notification to AyServer, but only if Ay is registered to AyServer. A message is shown on display informing about Ay intention (see Figure 5- 86 Sending SHUTDOWN notification to AyServer).